Nilfisk-Advance America IVB 3-M ユーザーズマニュアル

ページ / 18
15
english
IVB 3-M
IVB 5-M
IVB 7-M
1) 
Option depending on model
 
   
EC declaration of conformity
NILFISK-ADVANCE A/S
Sognevej 25
DK-2605 Brøndby
Product:
Model:
Description:
The design of the appliance 
corresponds to the following 
pertinent regulations:
Applied harmonized standards:
Applied national standards and 
technical specifications:
Jørgen Jensen
Vacuum cleaner for wet and dry operation
IVB 3-M/5-M/7-M
110/230-240 V~, 50/60 Hz, 1200 W, Dust class M
EC Machine Directive 98/37/EC
EC Low Voltage Directive 73/23/EC
EC EMC Directive 2004/108/EC
EN 12100-1, EN 12100-2
EN 60335-1
EN 60335-2-69
EN 55014-1, EN 55014-2, EN 61000-3-2
DIN EN 60335-1
DIN EN 60335-2-69
Brøndby, 04.07.2005
9.5 Optional 
Accessories
Description
Order No.
3-M
5-M
7-M
Filter bag (5 pcs.)
302000565
302001138
302001909
Waste bag (5 pcs.)
302001310
302001311
302001480
Filter element 
302000461
302000726
Cloth insert filter
302001370
302001371
Protective filter bag 
(10 pcs.)
30082
Filter screen
15475
Nilfisk-Alto-Foam-
Stop (6 x 1 l)
8469
9.6 
EC declaration of conformity
9.4 Technical 
data 
IVB
3-M
5-M
7-M
EU
GB
230/240V
GB
110V
EU
GB
230/240V
GB
110V
EU
GB
230/240V
GB
110V
Voltage
V
230
230/240
110
230
230/240
110
230
230/240
110
Mains frequency
Hz
50/60
Fuse
A
16
13
16
13
16
13
16
Power consumption
W
1200
Connected load for 
appliance socket
W
2400
1800
560
2400
1800
560
2400
1800
560
Total connected load
W
3600
3000
1760
3600
3000
1760
3600
3000
1760
Air flow rate
l/min
3600
Vacuum
mbar/kPa
230/23
Measurement area sound 
pressure level at a distance of 1 
m, EN 60704-1
dB(A)
62
60
Sound level
dB(A)
59
57
Power cord: Length
m
7.5
Power cord: Type
H05RR- F3G1.5
H07BQ-
F3G1.5
H05RR- F3G1.5
H07BQ-
F3G1.5
H05RR- F3G1.5
H07BQ-
F3G1.5
Protection class
I
Type of protection 
(splash water protec-
ted)
 IP X4 
Radio interference level
EN 55014-1 
Tank volume
l
27
45
70
Width
mm
380
476
580
Depth
mm
390
506
605
Height
mm
570
655
970
Weight
kg
10
14
27
Suction hose diameter 
mm
Minimum air flow volume
l/min
Associated negative pressure 
between suction hose/tool
Pa
27
690
16300
32
970
15700
38
1360
13900
50
2360
7800