Flue systems SGS
Installation options
B23
C13
C33
C53
C43
A SGS water heater should be installed according category B23, 
C13, C33, C43 or C53*.  
Concentric
Diameter (mm) 
80/125 
100/150  100/150  100/150  130/200  130/200
Max. length (m) 
40  
40  
40  
15  
15  
15 
Max. 45/90° bends 
3
Parallel (standard diameter)
Diameter (mm) 
80 
100 
100 
100 
130 
130
Max. length (m) 
25  
80  
45  
25  
115  
60 
L
equivalent
/bend 90° (m)  3,9  
4,6  
4,6  
4,6  
2,4  
2,4 
L
equivalent
/bend 45º (m)  1,1  
1,2  
1,2 
1,2  
1,4  
1,4 
Parallel (larger diameter for more length)
Diameter (mm) 
100 
130 
130 
130 
150 
150
Max. length (m) 
100 
100 
100 
100 
100 
100
L
equivalent
/bend 90º (m)  4,6  
2,4  
2,4  
2,4  
2,6  
2,6 
L
equivalent
/bend 45º (m)  1,2  
1,4  
1,4  
1,4  
1,6  
1,6 
*   All SGS are also approved for installations where the unit is supplied 
  without venting materials (C63).
Concentric flues
It is not permitted to use more than the specified number of 
bends, even when the duct is shorter than the maximum 
length. A 45° bend is equivalent to a 90° bend.
Parallel flues
-  The maximum permissible length should be reduced by the 
  equivalent length of each bend. (Note: for a parallel installation 
  this means that 3 changes in direction amount to 6 bends 
  (3 in the supply duct and 3 in the flue). 
-   The maximum length also applies if a parallel installation has 
  different supply and flue duct lengths (B23, C53).
-   Combined flues (C43) shall be fitted with a condensate drain. 
Note: horizontal flue runs must be installed with a fall of at least 
5 mm per metre.
SGS 28
SGS 30
SGS 50
SGS 60
SGS 80
SGS 100
Flue systems SGS
Minimum space requirements
SGS 28
SGS 30
SGS 50
SGS 60
SGS 80
SGS 100
Minimal space for wall duct (mm)
550 
550 
550 
550 
640 
640
725 
790 
790 
790 
940 
940
1630 
2170 
2170 
2170 
2230 
2230
1460 
1480 
1480 
1480 
1620 
1620
Y * 
1010 
1030 
1030 
1030 
1170 
1170
Minimal space for roof duct (mm)
1305 
1500 
1500 
1500 
1730 
1730
680 
1035 
1035 
1035 
1120 
1120
3060 
3420 
3420 
3420 
3620 
3620
X ** 
2110 
2470 
2470 
2470 
2670 
2670
1575 
1415 
1415 
1415 
1560 
1560
Y ** 
625 
465 
465 
465 
610 
610
For the parts numbers of components and flue gas ducts, etc.
please refer to the “Maintenance and accessories” chapter.
*   Distance without concentric pipe between bend and wall duct. 
**  Distance without concentric pipe between appliance and roof duct.
Ø80/125  Ø100/150  Ø100/150  Ø100/150  Ø130/200  Ø130/200
SGS 28-60
SGS 80-100