DIAGNOSTIC CODES 
DISPLAY SHOWS
INDICATES
CORRECTIVE ACTION
UPPER ELEMENT 
CONNECT 
FAULT
1.  Upper element is not functioning
Turn off power at the circuit breaker/fuse 
1. 
box and check for a loose connection at the 
element. For access directions see “Heating 
Element Replacement” section. If error persists 
proceed to the next step.
Replace non-functioning element. See “Heating 
2. 
Element Replacement” section.
LOWER ELEMENT 
CONNECT 
FAULT
1.  Lower element is not functioning
Turn off power at the circuit breaker/fuse 
1. 
box and check for a loose connection at the 
element. For access directions see “Heating 
Element Replacement” section. If error persists 
proceed to the next step.
Replace 
2. 
non-functioning
 element. See “Heating 
Element Replacement” section. 
IMPORTANT:
 Using an element greater 
than 2000 watts in place of the lower element 
will damage the water heater and void the 
warranty.
HEAT PUMP 
CONNECT 
FAULT
1.  Heat Pump compressor is not 
functioning. 
1.  Contact a qualified person to service the heat 
pump.
FAN 
CONNECT 
FAULT
1.  Heat Pump fan is not functioning. 
Contact a qualified person to service the unit. 
1. 
AMBIENT TEMP
SENSOR SHORT OR OPEN
OR AD ERROR
1.  Ambient Temperature Sensor is not 
functioning.
Contact a qualified person to service the unit.
1. 
UPPER TEMP
SENSOR SHORT OR OPEN
OR AD ERROR
1.  Upper Temperature Sensor is not 
functioning.
Contact a qualified person to service the unit.
1. 
LOWER TEMP
SENSOR SHORT OR OPEN
OR AD ERROR
1.  Lower Temperature Sensor is not 
functioning.
Contact a qualified person to service the unit.
1. 
DISCHARGE TEMP
SENSOR SHORT OR OPEN
OR AD ERROR
1.  Discharge Temperature Sensor is not 
functioning.
Contact a qualified person to service the unit.
1. 
COIL TEMP
SENSOR FAULT
OR AD ERROR
1.  Coil Temperature Sensor is not 
functioning.
Contact a qualified person to service the unit.
1. 
MAIN CIRCUIT BOARD 
FAULT
1.  Main Circuit Board is not functioning.
Contact a qualified person to service the unit.
1. 
HIGH TEMP
LOCKOUT
1.  Water temperature in unit has 
exceeded 190° F.
1.  See “Safety Shut-off” section.
CONDENSATE 
DRAIN 
ALARM
(If Accessory Condensate 
Pump is Installed)
1.  Condensate pump failure.
Check to see if accessory condensate pump is 
1. 
plugged in and has power. Also check circuit 
breaker/fuse box and GFCI (if used).  if error 
persists proceed to the next step.
Check condensate pump outlet tube for 
2. 
blockage. if error persists proceed to the next 
step.
Check control wire connections to condensate 
3. 
pump. If error persists proceed to the next step.
Replace accessory condensate pump. If error 
4. 
persists contact a Qualified Person.
NOTE:
 The diagnostic codes listed above are the most common. If a diagnostic code not listed above is displayed, 
contact Residential Technical Assistance referencing the number on the front of this manual.