Univex 318258-000 ユーザーズマニュアル

ページ / 20
8
Locate the hot water (outlet) & cold water (inlet) pipes 
4. 
to the water heater.
Locate the slit running the length of a section of pipe 
5. 
insulation.
Spread the slit open and slip the insulation over the 
6. 
cold water (inlet) pipe. Apply gentle pressure along the 
length of the insulation to ensure that it is fully seated 
around the pipe. Also, ensure that the base of the 
insulation is fl ush with the water heater. Once seated, 
secure the insulation with duct tape, electrical tape, or 
equivalent.
Repeat steps 5 and 6 for the hot water (outlet) pipe.
7. 
Add additional sections of pipe insulation as needed.
8. 
Figure 6  
T&P Relief Valve Insulation 
T&P Relief Valve
T&P Relief Valve 
Drain Line
Manual Relief Lever
T&P Relief Valve Insulation
Electrical Requirements
If you lack the necessary skills required to properly install the 
electrical wiring to this water heater, do not proceed but have a 
qualifi ed electrician perform the installation.
When making the electrical connections, always make sure:
The electrical service provides 240 VAC to the water heater 
• 
for proper operation. DO NOT use 208 VAC.
Wire sizes and connections comply with all applicable 
• 
codes or in the absence of local or state codes follow 
NFPA-70, the National Electrical Code-current edition.
Wiring enclosed in approved conduit (if required by local 
• 
codes).
The water heater and electrical supply are properly  
• 
grounded.
The electrical supply has the proper overload fuse or 
• 
breaker protection.
Figures 8A & 9 are provided as reference drawings. Always 
reference the wiring diagram located on the water heater for the 
correct electrical connections and 
connect the electrical supply 
to the water heater in accordance with local utility requirements 
and codes.
When installing the electrical wiring to the water heater:
Although this water heater is equipped with “Dry Fire” 
1. 
protection circuitry, be sure tank is completely filled with 
water, and all air is purged from the tank before making 
any electrical connections. See “Draining and Flushing 
Section”.
Turn off power to the electrical wiring for the water heater at 
2. 
the circuit breaker/fuse box.
Remove the left louvered access panel (when facing the 
3. 
water heater) by loosening the screws securing it to the 
water heater.
Loosen the screws securing the electrical junction box 
4. 
cover to the water heater and set aside. 
Connect the electrical supply to the water heater.  
5. 
A standard 1/2 inch opening has been made in the junction 
box for conduit connections. 
Connect ground wire to green ground wire in the electrical 
6. 
junction box of the water heater.  
Reinstall the junction box cover.
7. 
Reattach the left louvered access panel to the water heater 
8. 
and secure it using the screws loosened earlier.
Turn on electrical power to the water heater.
9. 
Press the power button to turn the water heater on, then 
10. 
press the Efficiency button to set the operating mode. 
NOTE:
 The water heater will conduct a system diagnostic  
(approximately 8 minutes) prior to returning to operation.
Once the diagnostic sequence has finished, the fan should 
11. 
turn on.  
NOTE:
 The heat pump’s fan will not turn on if the incoming 
water temperature is less than 59 °F and/or the ambient 
air temperature is above 109 °F or below 45 °F. Should the 
internal diagnostics detect a problem with the heat pump, 
an error message will be displayed. 
Set the operational mode. For standard installation, the 
12. 
Hybrid Mode offers the best combination of efficiency 
and hot water delivery. For detailed descriptions of all 
operational modes see “Adjusting the User Interface 
Module/Operational Modes” section.
WARNING
Electric Shock Hazard
Disconnect power before 
servicing.
Replace all parts and panels 
before operating.
Failure to do so can result in 
death or electrical shock.
 
 
 
 
WARNING
Fire Hazard
Use 10 gauge solid copper 
wire.
Use a UL listed or 
CSA approved strain relief. 
Connect ground wire to green 
ground wire.
Failure to do so can result in 
death, fire, or electrical shock.
Figure 7
Louvered Panel