Explosion Hazard
Flammable hydrogen gases
may be present.
Keep all ignition sources away
from faucet when turning on
hot water.
Do not smoke or have open flame or sparks in vicinity of heater. 
Do not mix uN•LIme with other chemicals. Do not allow contact 
with magnesium, aluminum or galvanized metals.
Chemical Hazard
• Product contains phosphoric acid.
• Keep out of reach of children.
• Use rubber or neoprene gloves.
Contains  phosphoric  acid.  In  case  of  external  contact,  flush 
with  cool  water.  If  irritation  persists,  get  medical  attention.  If 
swallowed, give 1 or 2 glasses of water or milk and call physician.
get immediate medical attention for eyes. Keep out of reach of 
children.
note: the use of rubber or neoprene gloVes is 
recommended, especially if you haVe any open 
sores or cuts to aVoid unnecessary irritation 
or discomfort.
1.  Turn  off  fuel  and/or  power  supply  to  heater.  Also,  turn 
off  power  to  any  electrical  device  or  equipment,  which  is 
attached, or part of the system.
2.  open  hot  water  side  of  faucet  closest  to  heater  and  allow 
water to run until it is cool enough to handle safely.
3.  Close cold water inlet valve to heater.
4.  Connect  hose  to  drain  valve  at  bottom  of  heater  and  start 
draining heater into suitable floor drain area.
5.  remove relief valve while heater is draining. NoTe: Do not 
replace relief valve until deliming is completed. relief valve 
opening will also act as a vent in case of possible contact 
between  the  delimer  and  the  anode  rod(s),  which  may 
produce flammable hydrogen-air mixtures.
6.  If relief valve appears to be limed-up, place it in a clean glass 
or  plastic  container  adequate  in  size  so  that  you  can  pour 
enough uN•LIme® into the container to cover the valve and 
allow space for foaming. When foaming stops, run fresh cool 
water into the container and rinse the relief valve for a few 
minutes.
7.  If  heater  does  not  drain  completely  after  a  reasonable 
length of time, turn off the main water supply valve to stop 
water  from  entering  the  tank  due  to  a  by-pass  problem  or 
defective cold water inlet valve. Also, check for clogged drain 
valve  opening.  Heater  must  be  completely  drained  before 
introducing uN•LIme.
deliming solVents
A.  o.  Smith  recommends  the  use  of  uN•LIme  for  deliming.  
uN•LIme is a patented food grade acid which is safe to handle 
and  does  not  create  the  harmful  fumes  which  are  associated 
with other products.
uN•LIme may be obtained from your dealer, distributor or A. o. 
Smith Product Service Division. order Part Number 9005416105, 
1 gallon, packed 4 gallons per case or Part Number 9005417105, 
5 gallon  container.
NoTe: un•Lime is not available for use in Canada.
Hydrochloric base acids are not recommended for use on glass 
lined tanks.
observe handling instructions on label of product being used. 
tank cleanout procedure
The  following  practices  will  ensure  longer  life  and  enable  the 
unit to operate at its designed efficiency:
1.  once a month the heater should be flushed. open the drain 
valve and allow two gallons of water to drain from the heater. 
Inlet water valve should remain open to maintain pressure 
in tank.
2.  A cleanout opening is provided for periodic cleaning of the 
tank. gas must be shut off and heater drained before opening 
cleanout.
To clean heater through cleanout opening, proceed as follows:
3.  Drain heater.
4.  remove outer cover plate from lower side of heater jacket.
5.  remove six (6) hex head screws securing tank cleanout plate 
and remove plate.
6.  remove lime, scale, or sediment using care not to damage 
the glass lining.
7.  Inspect  cleanout  plate  gasket,  if  new  gasket  is  required, 
replace with part no. 9004099215.
8.  Install  cleanout  plate.  Be  sure  to  draw  plate  up  tight  by 
tightening screws securely.
9.  replace outer jacket cover plate. 
In some water areas the sediment might not be removed by this 
method and may result in the water heater making rumbling or 
boiling  noises.  To  dissolve  and  remove  these  more  stubborn 
mineral  deposits,  A.  o.  Smith  uN•LIme  Professional  Delimer 
should be used.
deliming using flo-jug method
uN•LIme in the 5 gallon size is recommended for deliming of all 
models. Contact your local A.o. Smith dealer, distributor or, A.o. 
Smith Water Products Company:
 
Telephone: (800) 433-2545
 
fax:  (800) 433-2515
 
Website:  www.hotwater.com/parts
Prepare the Water Heater
To  delime  the  water  heater  using  the  flo-Jug  method,  first 
prepare the heater for deliming.