Rinnai R75LSI ユーザーズマニュアル

ページ / 44
 
VA Series Indoor LS Manual 
Switch No.
F
O
F
8
5
7
6
4
3
ON
1
2
Switch No.
F
O
F
8
5
7
6
4
3
ON
1
2
120º F (49º C) 
140º F (60º C) 
  Setting the Temperature
                                 
1.  Press the “Priority button” on the 
temperature controller.  The 
green Priority light will glow 
indicating that this controller is 
controlling the temperature and 
that the Rinnai water heater is 
ready to supply hot water. 
While any hot water is being 
provided, the temperature setting can 
only be adjusted between 98º F and 
110º F. 
NOTICE 
          DANGER 
Hot water can be dangerous, especially for infants or children, the elderly, 
or infirm.  There is hot water scald potential if the thermostat is set too high. 
Water temperatures over 125º F (51º C) can cause severe burns or 
scalding resulting in death. 
Hot water can cause first degree burns with exposure for as little as: 
3 seconds at 140º F (60º C) 
20 seconds at 130º F (54º C) 
8 minutes at 120º F (48º C) 
Test the temperature of the water before placing a child in the bath or 
shower. 
Do not leave a child or an infirm person in the bath unsupervised. 
 
The priority can only be changed 
while no hot water is running. 
  Temperature Options Without a Temperature Controller   
         
The default temperature setting for this appliance 
installed without a temperature controller is 120º F 
(49º C).  If desired the temperature setting can be 
changed to 140º F (60º C) by adjustment of a dip 
switch. 
Set dip switch 5 to ON to obtain 140º F water 
temperature setting. 
Set dip switch 5 to OFF (default) to obtain 120º F 
water temperature setting. 
2. Press 
the 
▲ or ▼ buttons to 
obtain the desired temperature 
setting. 
 
All hot water sources are able to 
provide water at this temperature 
setting until it is changed again at 
this or another temperature 
controller. 
Check local codes for the maximum 
water temperature setting allowed 
when used in nursing homes, 
schools, day care centers, and all 
other public applications. 
NOTICE 
If a newly installed unit with a 
controller has not been powered for 
at least 6 hours then the temperature 
will return to the default setting of 
104º F (40º C) if power is interrupted. 
NOTICE 
There may be a variation between 
the temperature displayed on the 
temperature controller and the 
temperature at the tap due to 
weather conditions or the length of 
pipe to the water heater. 
NOTICE 
     WARNING 
DO NOT adjust the other dip 
switches unless specifically 
instructed to do so.