Rinnai R63LSE2 ユーザーズマニュアル

ページ / 40
 
 
VA Series Outdoor LS Manual 
  Temperature Ranges
   
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
This water heater will attempt to provide hot water at the temperature setting even when the water flow is varied 
or when more than 1 tap is in use.  The water heater can deliver water at only one temperature setting at a time.  
The available temperatures for a given model are provided below. 
  Setting the Sound Volume
 
(Voice Prompt)
   
 
 
 
 
 
 
 
 
 
BC-100V 
Press the “Sound Vol.” button to 
adjust the voice prompt volume.   
The default sound volume is set 
to Medium.  Each subsequent 
press of the button cycles 
through the volume levels in the 
order below. 
MC-100V  Press the “Function” button to 
adjust the voice prompt 
volume.  The default sound 
volume is set to Medium.  
Each subsequent press of the 
 or 
 button cycles through 
the volume levels in the order 
below. 
Medium Volume 
(default) 
High Volume 
Off Volume  
(beep) 
Off Sound  
(no beep) 
Low Volume 
Model 
R63LSe2
R75LSe 
98  100 102 104 106 108 110 115 120 
125  
130
135
140
150  
** 
160
**  
 
R94LSe 
R98LSe 
R98LSe-ASME 
98  100 102 104 106 108 110 115 120 
125
130
135
140
150
** 
160
** 
185
** 
Temp in Celsius  ºC 
37 
38 
39 
40 
41 
42 
43 
46 
49 
52  
54  
57  
*   
60  
66 
** 
71 
** 
85 
** 
Temperature Settings Available (ºF)  
Suggested temperatures are 
Kitchen 120 
º
F (49º C) 
Shower 98º - 110º F (37º - 43º C) 
Bath Fill  102º - 110º F (39º - 43º C) 
These temperatures are suggestions only. 
A temperature lower than 98º F (37º C) can be 
obtained at the tap by mixing with cold water. 
To change the temperature scale from Celsius to Fahrenheit or vice versa, press and hold the “On/Off“ button for 
5 seconds while the water heater is OFF. 
The MCC-91 controller is intended for commercial and hydronic applications only. If an MCC-91 controller is 
used in a residential dwelling for a hydronics application, a mixing valve must also be installed to limit the 
potable hot water temperature to a safe temperature. Water temperatures over 125º F (51º C) can cause 
severe burns or scalding. Refer to the Danger Alert on water temperatures. Rinnai shall not, in any event, be 
liable for damages resulting from such misuse or misapplication.  
**  MCC-91 Temperature Controller 
 
These settings require the MCC-91 controller.  When the MCC-91 controller is connected, these higher 
temperatures are available on all controller models in the system. Use of an MCC-91 controller in a residential 
dwelling will reduce the warranty coverage to that of a commercial warranty application. 
*  Re-setting the Maximum Temperature 
 
If the model name on the side of the water heater ends with “-UC” (ex. “REU-VA2535WD-UC”), then these 
units have a default maximum temperature of 120º F (49º C) and an option to increase the maximum 
temperature to 140 ºF (60 ºC).  Temperature settings from 125-140 ºF (52-60 ºC) are available by setting dip 
switch 6 to ON in the SW1 bank of 8 dip switches.    
 
Units with model names ending in “-US” have a default maximum temperature of 140 ºF (60 ºC).