Rinnai REU-V2526W-US プリント

ページ / 2
2526W SP-1 
R70e (2526W)    
Type of Appliance 
Rinnai model number 
Operation 
Exhaust system  
Minimum/Maximum Gas Rate (Input) 
Electrical 
 
Electrical Consumption 
 
 
Ignition System 
Hot Water Capacity 
Temperature 
Temperature (without remote)  
Approved Gas Types 
Installation 
Energy Factor 
Thermal Efficiency 
Service Connections 
 
 
Water Flow Control 
Minimum/Maximum Water Supply Pressure 
Temperature controlled, continuous flow, gas hot water system 
REU-V2526W-US 
With or without remote controls, mounted in kitchen, bathroom, etc. 
Outdoor forced combustion 
15,000 - 199,000 BTU/h (Natural Gas or Propane) 
Appliance: 
 
 
AC 120 Volts - 60 Hz 
Remote Control: 
 
DC 12 Volts 
Normal 
   63 
watts 
Standby   5.5 
watts 
Anti-frost protection 
 
84 watts 
Direct electronic ignition 
0.6 to 6.5 GPM (50° F rise) 
0.6 to 7.0 GPM (35° F rise) 
98° - 140° F  
120° F (factory default) 
Natural or Propane (ensure unit matches gas type) 
Outdoors only 
Natural Gas: 0.81 
 
Propane: 0.80 
Natural Gas: 84% 
 
Propane: 84% 
Gas supply: 3/4 inch MNPT 
Cold water inlet: 3/4 inch MNPT 
Hot water outlet: 3/4 inch MNPT 
Water flow sensor, electronic water control and by-pass control  
20 - 150 PSI (50 PSI or above is recommended for maximum flow) 
2526W SP-1                          4/2007 
FLOW TABLE 
Water Flow Capacity Curves 
(For 1 to 5 units manifolded in parallel) 
© 2005 Rinnai Corporation 
0.0
5.0
10.0
15.0
20.0
25.0
30.0
35.0
40.0
0
25
50
75
100
125
150
T – Temperature Rise (°F)
H
o
t W
a
te
F
lo
w
 R
a
te
 (
g
p
m
)
1 Unit
2 Units
3 Units
4 Units
5 Units