Rinnai REU-VA3237W プリント

ページ / 2
R98LSe (VA3237W)  
Type of Appliance 
Rinnai model number 
Operation / Installation 
Minimum/Maximum Gas Rate (Input) 
Electrical 
 
Electrical Consumption 
 
 
Ignition System 
Hot Water Capacity 
Temperature 
 
Temperature (without remote)  
Approved Gas Types 
Thermal Efficiency 
Service Connections 
 
 
Water Flow Control 
Minimum/Maximum Water Supply Pressure 
Temperature controlled, continuous flow, gas hot water system 
REU-VA3237W 
Forced combustion; outdoor only 
19,000 - 237,000 BTU/h (Natural Gas or Propane) 
Appliance: 
 
 
AC 120 Volts - 60 Hz 
Controller: 
  DC 
12 
Volts 
Normal 
   99 
watts 
Standby   2 
watts 
Anti-frost protection 
 
116 watts 
Direct electronic ignition 
0.6 to 7.9 GPM (50° F rise) 
0.9 to 9.8 GPM (35° F rise) 
98° - 140° F  (98° - 185° F available with the MCC-91 controller for 
commercial and hydronic applications) 
120° F (factory default) 
Natural or Propane (ensure unit matches gas type) 
Natural Gas: 83% 
 
Propane: 83% 
Gas supply: 3/4 inch MNPT 
Cold water inlet: 3/4 inch MNPT 
Hot water outlet: 3/4 inch MNPT 
Water flow sensor, electronic water control and by-pass control  
15 - 150 PSI (50 PSI or above is recommended for maximum flow) 
© 2008 Rinnai Corporation 
R98LSe SP                            5/2008 
FLOW TABLE 
Water Flow Capacity Curve 
 
0
1
2
3
4
5
6
7
8
9
10
0
25
50
75
100
125
150
delta T-Temperature Rise(F)
W
a
te
r F
lo
w
 R
a
te
 (
G
PM