Honeywell TL6120 ユーザーズマニュアル

ページ / 4
TL6120
      69-1904EF                    1/16/06                    1/2
The TL6120 thermostat can be used to control an electric heating
system such as a baseboard heater, a radiant floor, a radiant ceiling,
a convector, a fan-forced heater, etc.
The clock must be set when TIME flashes on the screen. 
n
Press the 
 button to set the day.
o
Use the 
 and 
 buttons to set the clock.
p
Press the 
 button to exit.
To use the Automatic mode, press the 
 button  until
AUTO is selected (outlined) on the screen. The current
period number will appear. 
In this mode, the thermostat automatically adjust its
temperature setpoint according to the period of the day
(wake up, leave for work, return home and sleep).
You can program up to 4 periods in a day. You can set 2 different
programs: one for the weekdays (Monday to Friday) and another one
for the weekend (Saturday and Sunday).
The thermostat is preprogrammed with the following schedule:
To temporarily override the current setpoint, set the desired
temperature using the 
 buttons. The new setpoint will be used
until the beginning of the next period.
To modify the schedule:
n
Press the 
 button until AUTO is selected.
o
Press the 
 button.
Each time you press the 
 button, the thermostat displays one of
the periods in the following order (from left to right):
p
Set the start time for the period using the 
 and 
 buttons.
NOTE: To disactivate the period, press the 
 button.  Instead 
of displaying the start time of the period, the thermostat will dis-
play --:--. During operation, the thermostat will skip over that 
period.
q
Set the temperature for the period using the 
 buttons.
r
Repeat steps 2 to 4 for the remaining periods.
s
Press the 
 button to return the thermostat to normal display.
TL6120
User Guide
5-2 Programmable Thermostat
Period no. in 
automatic mode
Temperature *
Heating power 
indicator
Time and day
Manual 
mode
Automatic 
mode
Economy 
mode
Period no. in 
economy mode
Appears if the 
thermostat is configured 
for a fan-forced heater
Appears during 
a power failure
Appears when the 
setpoint is displayed
Flashes when the 
clock has been reset
Display
* The thermostat normally displays the actual (measured) temperature. 
To view the set temperature (setpoint), press either of the 
 buttons once.
Up/Down buttons
Mode button
Day button
Hour button
Program button
Return button
Screen
Minute button
Pull cover down
n
Description
1.
o
Clock and Day Setting
2.
p
Automatic (programmable) mode
3.
Period
Monday to Friday
Saturday & Sunday
Start Time
Temperature
Start Time
Temperature
1
Wake
6:00
21°C (70°F)
6:00
21°C (70°F)
2
Leave
8:00
16°C (62°F)
--
--
3 Return
18:00
21°C (70°F)
--
--
4
Sleep
22:00
16°C (62°F)
22:00
16°C (62°F)
Monday to Friday
Saturday and Sunday
 MO TU WE TH FR
 SA SU
1
2
3
4
1
2
3
4