ritetemp 8050C ユーザーズマニュアル

ページ / 10
8050C Features
PG
 17
PG
 18
STEP 1 - Connect the wire to 
the G terminal on the thermostat. 
This connects the Fan.
STEP 2 - Add a jumper wire 
between W and Y.
STEP 3 - Connect the Y wire to 
the terminal on the thermostat. 
This connects the Compressor.
STEP 4 - Connect the or B wire to the 
or B terminal on the thermostat. (If you have both 
O and wires, use the O and tape off the B).
This connects the change over valve.
STEP 5 - Connect the wire to the RC terminal on 
the Thermostat. This connects to the 24vac power. 
STEP 6 - Connect W or W2 to W2 on the thermostat. 
This connects the AUX heat.
Your HVAC system is now connected to the thermostat.
   Go To Page 10
HEAT PUMP
with Auxiliary Heat 
NOTE: Wires marked with 
the dotted line are optional.
O  or  B
(not both)
HEAT PUMP 
Change
Over
AUX
Heat
G
O or B
R
C
FAN
Y
 
Comp
24VAC 
Power
jumper
wire
jumper
wire
Thermostat
B
G
Y
R
C
From heat p
ump
with Aux hea
t
O
or
or 
W2
HEA
T    
      
 COO
L
AUT
O    
    O
N
OFF
FAN
The 8050C can be used with most 24-volt gas, oil or electric heating and air 
conditioning systems, all heat pumps, and gas millivolt heating systems. It cannot be 
used with 120 volt heating systems.  Ask The Home Depot for other thermostats 
to control line voltage systems.
The 8050C is programmable. There are 4 programming periods per day. Each period 
can be programmed separately.
You can use the built-in time/temperature programs, or alter 
them to suit your schedule. The 8050C separately programs 
each day of the week for both heating and cooling. You can 
easily override the programmed temperatures for as little as one 
programming period or up to an entire vacation.
The large backlit liquid crystal display shows time, day of the week, room and set 
temperatures. It will also remind you when the filter should be changed in your blower.
Temperature swing adjustment lets you fine-tune your system for maximum comfort 
and energy efficiency.
A 5-minute minimum off time protects your compressor system from being damaged.
Two "AA" batteries are used to retain your time and temperature programs and to run 
the thermostat.