Siemens 21-115532-001 ユーザーズマニュアル

ページ / 28
 
SPECIAL FEATURES 
 
 
 
VARI-AMP
TM
 RANGE AND CURRENT RATINGS AVAILABLE 
 
±10% 
±8 3/4%
±7 1/2%  ±6 1/4% 
±5% 
10-02.5-050.0 200  220  240 270 
320 
10-02.5-075.0
300
330
360 405 
480
10-02.5-100.0
400
440
480 540 
640
10-02.5-167.0
668
668
668 668 
668
10-02.5-250.0
   1000
1000
1000 
1000 
1000
10-02.5-333.0
   1332
1332
1332 
1332 
1332
11-02.5-416.3 
    1665 
1665 
1665 
1665 
1665 
10-05.0-050.0 100  110  120 135 
160 
10-05.0-100.0
200
220
240 270 
320
10-05.0-167.0
334
367
401 451 
534
10-05.0-250.0
500
550
600 668 
668
10-05.0-333.0
668
668
668 668 
668
11-05.0-416.3 835  835  835 835 
835 
10-07.6-038.1 
50 
   55 
     60 
    68 
        80 
10-07.6-057.2 
75 
   83 
     90 
   102 
          120 
10-07.6-076.2
100
110
120 
   135 
          160
10-07.6-114.3
150
165
180 
    203 
          240
10-07.6-167.0
219
241
263 296 
351
10-07.6-250.0*
328/347
361/381
394/416 443/468 
525/555
10-07.6-333.0*
437/463
481/509
524/556 590/625 
668/668
10-07.6-416.3*
546/578
601/636
656/668 668/668 
668/668
10-07.6-500.0
656
668
668 
     668 
668
10-07.6-667.0
875
875
875 
     875 
875
11-07.6-889.0 
1167 
1167 
1167 
     1167 
1167 
10-13.8-069.0 
50 
55 
60 
68 
  80 
10-13.8-138.0
100
110
120 135 
160
10-13.8-207.0
150
165
180 203 
240
10-13.8-276.0 200  220  240  270 
320 
10-14.4-072.0 
50 
55 
     60 
      68 
80 
10-14.4-144.0 100  110  120  135 
160 
10-14.4-288.0
200
220
240 270 
320
10-14.4-333.0
231
254
277 312 
370
10-14.4-432.0
300
330
360 405 
480
10-14.4-576.0
400
440
480 540 
640
11-14.4-720.0
500
550
600 668 
668
10-14.4-833.0 578  636  668  668 
668 
10-19.9-100.0 
50 
55 
60 
     68 
80 
10-19.9-200.0
100
110
120 135 
160
10-19.9-333.0
167
184
201 226 
268
10-19.9-400.0
200
220
240 270 
320
10-19.9-667.0
335
368
402 452 
536
11-19.9-833.0 418  459  502  565 
668 
Units with catalog number starting with: 
    10 are self cooled 
    11 are forced-air cooled 
Regulators can be modified at factory for 50 
Hz operation with appropriate de-rating of 
voltage. 
*Capable of carrying current corresponding 
to rated kVA when operated at 7200/12470 
volts ground wye. 
OPERATION AT LESS 
THAN 
RATED VOLTAGE 
JFR regulators may be operated at less 
than the voltage for which they were de-
signed. All system voltages for which 
control system taps have been provided 
are shown on the nameplate. When this 
is to be accomplished it may be neces-
sary to reconnect particular leads at the 
upper 19-pin terminal block as illustrated 
on page 5. When operating the regulator 
at reduced voltage it must be noted that 
the regulator carries a maximum current 
rating which rules regardless of the 
voltage (see table at right). It may 
therefore be necessary to operate the 
regulator at less than its nameplate kVA 
rating. 
Page 14