Manitowoc Ice K00364 ユーザーズマニュアル

ページ / 8
 
 
    
 
 
 
 
 
 
 
 
 
K00364 Electronic Bin Thermostat 
 
 
 
            
        Installation Instructions 
 
This kit reduces overfill and condensation issues and can be used on any Manitowoc ice machine installed on an ice 
dispenser.  Order kit number K00336 for the following models IB0620, IB0820, IB1020, QF0400 and QF2300. 
 
Control Settings 
 
Flake/Nugget/Chiplet: 
The control  must be reset  from the factory setting.  
Refer to the jumper and control settings.  
 
Ice Cube Machines: 
The machines use the factory control settings. 
 
The controller has a one-minute time delay anytime 
power is interrupted and restored. 
 
Positioning the Touchpad Jumpers 
 
P5 Jumper 
The P5 jumper position determines if the touchpad is 
locked or unlocked. The control is factory locked; to 
unlock, move the jumper from one pin to two pins. 
 
 
 
 
 
P4 Jumper 
The P4 jumper labeled Jump 1 is used to set the control 
for heating or cooling mode.  Jump 2 is used to 
establish set point at either cut-in or cut-out.  
 
 
 
 
 
 
 
 
 
   Cubers 
        Flake/Nugget/Chiplet 
 
 
 
Setting Control Set point Value 
 
To view and adjust set point, follow these steps: 
 
A.  Press MENU until the display flashes SP. 
B.  Press MENU again to display the existing set 
point value. 
C.  Press  up or down (arrows) to change the set 
point value. 
D.  Press MENU again to save the new value.  The 
display returns to the sensed temperature. 
E.  If no setup entry is made for 30 seconds, the 
control reverts to the normal temperature 
display. 
 
IMPORTANT: 
If MENU is not pressed after changing the set point 
value, the control reverts to the previously 
programmed set point value. 
 
 
 
 
 
 
 
 
 
 
RED 
SENSOR 
LEAD 
BLACK 
SENSOR 
LEAD 
JUMPER 
LOCATIONS 
MATCH 
WIRING  
TO ICE 
MACHINE 
VOLTAGE 
BIN SWITCH OR 
TOGGLE SWITCH