American Water Heater BCL3 85T390 6NOX ユーザーズマニュアル

ページ / 52
32
Contact  the  local  water  heater  supplier  or  service  agency  for 
further  information  concerning  an Anode  replacement  Kit  and 
this chlorination treatment.
If hot water odor persists after anode replacement and chlorination 
treatment, we can only suggest that chlorination or aeration of 
the water supply be considered to eliminate the water problem.
Do not remove the anode leaving the tank unprotected. by doing 
so, all warranty on the water heater tank is voided.
“air” in hot water fauCets
HYDrOGen  GAS:  Hydrogen  gas  can  be  produced  in  a  hot 
water system that has not been used for a long period of time 
(generally  two  weeks  or  more).  Hydrogen  gas  is  extremely 
flammable and explosive. To prevent the possibility of injury 
under  these  conditions,  we  recommend  that  the  hot  water 
faucet located farthest away from the water heater be opened 
for  several  minutes  before  any  electrical  appliances  which 
are connected to the hot water system are used (such as a 
dishwasher or washing machine). If hydrogen gas is present, 
there will probably be an unusual sound similar to air escaping 
through  the  pipe  as  the  hot  water  faucet  is  opened.  There 
must be no smoking or open flame near the faucet at the time 
it is open.
high water temperature shut off system
This water heater is equipped with a manual reset type high 
limit  (energy  Cutout)  switch.  The  high  limit  switch  interrupts 
the  main  burner  gas  flow  should  water  temperature  reach 
203°F (95°C).
In  the  event  of  high  limit  switch  operation,  the  water  heater 
cannot be restarted unless the water temperature is reduced to 
approximately 120°F (49°C). The high limit reset button on the 
front of the thermostat then needs to be depressed. See Figure 2 
for the location of the reset button.
start up Conditions
smoke/odor
It is not uncommon to experience a small amount of smoke and 
odor during the initial start-up. This is due to burning off of oil 
from metal parts, and will disappear in a short while.
strange sounds
Possible noises due to expansion and contraction of some metal 
parts during periods of heat-up and cool-down do not necessarily 
represent harmful or dangerous conditions.
Condensation causes sizzling and popping within the burner area 
during  heating  and  cooling  periods  and  should  be  considered 
normal.
operational Conditions
hot water odor
In  each  water  heater  there  is  installed  at  least  one  anode  rod 
for  corrosion  protection  of  the  tank.  Certain  water  conditions 
will cause a reaction between this rod and the water. The most 
common  complaint  associated  with  the  anode  rod  is  one  of  a 
“rotten egg smell” in the hot water. The smell is a result of four 
factors which must all be present for the odor to develop:
a.  A concentration of sulfate in the supply water.
b.  little or no dissolved oxygen in the water.
c.  A sulfate reducing bacteria which has accumulated within the 
water heater (this harmless bacteria is nontoxic to humans).
d.  An excess of active hydrogen in the tank. This is caused by 
the corrosion protective action of the anode.
Hot  water  odor  may  be  eliminated  or  reduced  in  some  water 
heater models by replacing the anode(s) with one of less active 
material,  and  then  chlorinating  the  water  heater  tank  and  all 
water lines.
for your information