American Water Heater STCE3-52/80/119 ユーザーズマニュアル

ページ / 76
OPERATION & SERVICE
Servicing should only be performed by a Qualified Service Agent
30
Contactor Configurations
This illustration shows how contactors are configured and how they provide power to the 
heating elements on Electronic Control Model water heaters, This is a redundant contactor 
configuration - two contactors must close their contacts to energize any heating element. 
Elements and Banks are numbered according to how the control system monitors them - 
see Element Sensors pages 27 and 28. There are two contactors installed for each Bank. 
IE: the illustration shows a 9 element configuration, a water heater factory equipped with 6 
heating elements would have 4 contactors and a water heater with 3 elements would have 2 
contactors. Wiring is shown for the first two heating elements in Bank 1 only for simplicity.
BANK 1 (LOWER)
BANK 2 (MIDDLE)
BANK 3 (UPPER)
1     2     3
Blk  Blk  Blu
1     2     3
Red  Yel  Red
4     5     6
Red  Yel  Red
4     5     6
Blk  Blk  Blu
7     8     9
Blk  Blk  Blu
7     8     9
Red  Yel  Red
7
8
9
4
5
6
1
2
3
 
 
 
 
 
 
 
 
 
BANK 1 (LOWER)
BANK 2 (MIDDLE)
BANK 3 (UPPER)
 
Heating Elements
Element Numbers/Connections
      Wire Colors to Elements
Heating Element Banks
Power
Connection
Terminals
Contactors
4     5     6
Red  Yel  Red
4     5     6
Blk  Blk  Blu
LEGEND