OperatiOn
control box installation
The following procedure outlines the steps for connecting 
the pump to a control box.
control box mounting
Mount  the  control  box  in  an 
upright vertical position
Make sure the control box is securely fastened to a flat 
surface, that is free of dust, dirt, moisture or any elements 
that may contaminate or erode the electronic components 
of the control box.
  danger
The  CX400  and  PX400  submersible 
pumps  are  also  designed  to  work  with 
a  control  box.This  control  box  contains 
the  necessary  electronics  (float  switch 
connections)  to  operate  the  pump. 
Remember  this  control  box  contains  hazardous 
voltages.  Disconnect  all  sources  of  power  before 
installing or servicing. There exists the possibility of 
electrocution, electric shock or burn, which can cause 
severe bodily harm or even 
death!
  danger
When  installing  the  control  box,  the 
possibility  exists  of  electrical  shock, 
electrocution and possibly death! 
never 
have  untrained  personnel  perform  the 
installation. 
alWaYS  have  qualified 
service  personnel  (licensed  electrician)  perform  the 
installation.
  Warning
Explosion or Fire Hazard exists if this pump 
is used with flammable liquids. 
do not use 
this pump with 
flammable liquidsdo not 
install this pump in hazardous locations as 
defined  by  the  National  Electrical  Code, 
ANSI/NFPA 70. 
Single-phase power installation (input)
The CX400/PX400 submersible pumps require 1Ø, 115 
VAC, 60 Hz, power for normal operation. 
If  you  cannot  determine  what  your  pump's  power 
requirements are, look at the vendor supplied identification 
name  tag  attached  to  the  pump  or  contact  Multiquip's 
service department.
power cord requirements
When routing the 115 VAC, 60 Hz., single phase power via 
a power cord to the control box, 
alWaYS use the correct 
wire size. Please refer to Table 4 to determine the correct 
wire  size.  Incorrect  wire  size  can  adversely  affect  the 
performance of the pump and may ultimately burn-out the 
pump motor.
NOTICE
Applying incorrect power (voltage or voltage phase) 
to the submersible pump can cause severe damage 
to the pump motor. Please make sure that the correct  
voltage and phase are connected to the pump motor 
at all times.
Table 4. power cord length 
and Wire Size
AMPS
50 Ft. 
(15.24 m)
100 Ft. 
(30.48 m)
150 Ft. 
(45.72 m)
6
16 AWG
16 AWG
14 AWG
8
16 AWG
14 AWG
12 AWG
10
16 AWG
14 AWG
12 AWG
12
14 AWG
14 AWG
12 AWG
14
14 AWG
12 AWG
10 AWG
16
12 AWG
12 AWG
10 AWG