cx400/px400 Sub. pump • operation and partS manual — rev. #1 (12/03/10) — page 19
connecting  dual  float  Switch  (SW-1Wop) to 
control box
1.  Remove the float switch input connector housing, then   
route the float switch wires through the cable gland on 
the control box. Attach the wires of the float switch to 
the terminal block as indicated by Table 5 and Figure 10.
2.  Tighten  the  connector  housing  to  ensure  a  tight  fit 
between the cord and the connector body. This will 
prevent the cable from pulling out of the terminal block 
and also prevent moisture from entering the control 
box.
3.  Determine the tether length of the float switch wires 
then secure float switch wires to pump discharge hose. 
See Figure 8 or Figure 9 and Table 3 to determine the 
pumping range.
connecting ac power to the cb3 control box
1.  The AC input power cord (not included) should have 
three wires. Each wire is color coded. The colors are
 
WHiteblacK and green.
2.  Remove  the  AC  input  connector  housing  from  the 
control  box,  then  route  the  power  cord  through  the 
cable gland on the control box.
3.  Connect  the  AC  input  power  cord  to  the  contactor 
located inside the control box as shown in Figure 10, 
and Table 6.
Table 5. dual Float switch connections
Float 
Switch
Terminal 
block no.
Wire 
Color
Start
TB1-A1  
TB1-A2
Black 
White
Stop
TB1-B8  
TB1-B7
Black 
White
Table 6. 1Ø-115 vac power 
Connections 
Wire Color
Contactor.
BLACK
L1
WHITE
L2
GREEN
GROUND
OperatiOn
4.  Connect the other end of the  AC power cord to the 
voltage  source.  Remember  to  provide  a  means  of 
disconnecting the power from the control box (circuit 
breaker or quick disconnect switch). Also make sure 
to provide a good earth ground to the control box
Connecting AC Power to the Pump Motor
1.  AC power is routed to the pump motor via a contactor. 
The coil of the contactor is energized or de-energized 
by the opening and closing of the float switch contacts. 
2.  The power cord (included with pump) should have three 
wires. Each wire is color coded. The colors are 
WHite, 
blacK and green.
3.  Remove the pump AC input connector housing from 
the control box, then route the power cord through the 
cable gland on the control box.
4.  Connect pump power cord to the contactor as shown 
in Figure 10, and Table 7.
NOTICE
It is recommended that the power being supplied to the 
control box 
alWaYS be connected to a circuit breaker 
or  a 
quick  disconnect  switch. This  safety  feature 
allows for quick removal of power from the control box 
in the event of an emergency.
table 7. ac output power 
Connections To Pump 
Wire Color
contractor
BLACK
T1
WHITE
T2
GREEN
Ground