Adjustment
20
1
.04.11 
Height of the feed wheel 
(on the PFAFF 571)
Requirement
1.  When pressure is applied to the feed wheel 4, it should protrude from the needle plate 
by tooth height (approx. 0.8 mm)
2.  When no pressure is applied to the feed wheel 4 , it should have a vertical play  of ap-
prox. 0.3 mm.
 
● Swing out the roller presser.
 
● Loosen screws 1 and 2.
 
● Adjust drive wheel 3 according to requirement 1, taking care to see that the teeth of 
drive wheel 3 and feed wheel 4 lock into each other properly.
 
● Tighten screws 1.
 
● Adjust guide 5 according to requirement 2 and tighten screws 2.
Fig. 1 - 11
2
1
5
3
4
0,8 mm
0,3 mm