35
 
CLEANING AND MAINTENANCE 
VENT SYSTEM
The fireplace and venting system should be inspected before initial use and at least annually by a qualified field service person. 
Inspect the external vent cap on a regular basis to make sure that no debris is interfering with the airflow. Inspect entire venting 
system to ensure proper function.
GLASS 
PANELS
Thoroughly clean the inside of the glass 
panels
 after using the fireplace for ten hours. Periodically clean the glass 
panel
 as neces-
sary. 
When cleaning the glass, remember:
•     Do not remove the glass when hot. Allow glass to cool before removal.
•     NEVER use abrasive materials.
•     Keep children and pets a safe distance away.
•     Never operate the fireplace without the glass door properly secured.
•     Never operate the fireplace if the glass is broken.
•     Replace any glass that is chipped, cracked, or broken. Replacement glass door assemblies MUST be supplied by the fireplace 
manufacturer – No substitute materials may be used.
•     Handle glass door with care to avoid striking or scratching it on hard objects.
To clean glass door, follow “Glass Removal” procedure outlined in the Final Installation section. Film deposit on the inside of 
the glass should be cleaned off using a nontoxic, non-corrosive, non-abrasive, mild-cleaning solution. Simply apply an adequate 
amount to the glass and wipe off with a damp cloth. After all maintenance has been completed, re-install glass door.
STONES
Leave 
stones 
 installed in the fireplace for cleaning. Vacuum surface of the 
st    ones
 with a brush attachment. If 
stones
 must be  
removed 
for cleaning, handle carefully by holding gently. 
MEDIA
Replace or add media as required following unstallation instructions in the Final Installation  section of this manual
BLOWER/FAN ASSEMBLY
The fan assembly has an automatic temperature control which will turn the fan on as the fireplace heats up. The fan will turn off as
 
the fireplace cools down. The control knob can be used to turn the fan off or control the fan speed. The heat up time and cool down
time is controlled by the temperature disc magnetically mounted under the fireplace bottom.  This disc can be moved  to adjust the
blower start up and shut off timing.
  CAUTION:  Label  all  wires 
prior  to  disconnection  when 
servicing controls. Wiring errors 
can  cause  improper  and  dan-
gerous operation. Verify proper 
operation after servicing.