Franklin 2007 ユーザーズマニュアル

ページ / 75
Application – Three-Phase Motors
Advance Controls: MDR3 Overload
AEG Series: B17S, B27S, B27-2
ABB Type: RVH 40, RVH65, RVP160,  
 
 
T25DU, T25CT, TA25DU 
AGUT: MT03, R1K1, R1L0, R1L3, TE set Class 5
Allen Bradley: Bulletin 193, SMP-Class 10 only
 
Automatic Switch Types: DQ, LR1-D, LR1-F,   
 
LR2 Class 10
Benshaw: RSD6 (Class 10) Soft Start
Bharita C-H: MC 305 ANA 3 
Clipsal: 6CTR, 6MTR
Cutler-Hammer: C316F, C316P, C316S, C310-set  
 
at 6 sec max, Advantage Class10
Fanal Types: K7 or K7D through K400
Franklin Electric: Subtrol-Plus, SubMonitor
Fuji Types: TR-OQ, TR-OQH, TR-2NQ, TR- 3NQ,  
 
TR-4NQ, TR-6NQ, RCa 3737-ICQ & ICQH
Furnas Types: US15 48AG & 48BG, 958L,  
 
 
ESP100-Class 10 only, 3RB10-Class 10
General Electric: CR4G, CR7G, RT*1, RT*2,
 
RTF3, RT*4, CR324X-Class 10 only
Kasuga: RU Set Operating Time Code = 10 &    
 
time setting 6 sec max
Klockner-Moeller Types: ZOO, Z1, Z4, PKZM1,  
 
PKZM3 & PKZ2
Lovato: RC9, RC22, RC80, RF9, RF25 & RF95
Matsushita: FKT-15N, 15GN, 15E, 15GE, FT-15N,  
 FHT-15N
Mitsubishi: ET, TH-K12ABKP, TH-K20KF,  
 
 
TH-K20KP, TH-K20TAKF, TH-K60KF,  
 
 TH-K60TAKF
Omron: K2CM Set Operating Timing Code = 10 &  
 
time setting 6 sec max, SE-KP24E time setting
 
6 sec max
Riken: PM1, PM3
Samwha: EOCRS Set for Class 5, EOCR-ST,    
 
EOCR-SE, EOCR-AT time setting 6 sec max
Siemens Types: 3UA50, -52, -54, -55, -58, -59, -60,  
 
-61, -62, -66, -68, -70, 3VUI3, 3VE, 3UB
 (Class 
5)
Sprecher and Schuh Types: CT, CT1, CTA 1,   
 
CT3K, CT3-12 thru CT3-42, KTA3, 
 
CEF1 & CET3 set at 6 sec max, CEP 7 Class
 
10, CT4, 6, & 7, CT3, KT7
Square D/Telemecanique: Class 9065 Types:   
 
TD, TE, TF, TG, TJ, TK, TR, TJE &TJF (Class
 
10), LR1-D, LR1-F, LR2 Class 10, Types
 
18A, 32A, SS-Class 10, SR-Class 10 and
 
63-A-LB Series. Integral 18,32,63, GV2-L,
 
GV2-M, GV2-P, GV3-M (1.6-10 amp only)
 
LR9D, SF Class 10, ST Class 10, LT6 (Class
 
5 or 10), LRD (Class 10), Motor Logic  
 
 (Class10)
Recommended Adjustable Overload Relays
Toshiba Type: 2E RC820, set at 8 sec max.
WEG: RW2
Westinghouse Types: FT13, FT23, FT33, FT43, K7D, K27D, K67D,  
 
Advantage (Class 10), MOR, IQ500 (Class 5) 
Westmaster: OLWROO and OLWTOO suffi x D thru P
Other relay types from these and other manufacturers may or may 
not provide acceptable protection, and they should not be used 
without approval of Franklin Electric.
Some approved types may only be available for part of the listed 
motor ratings. When relays are used with current transformers, 
relay setting is the specifi ed amps divided by the transformer ratio. 
HP
KW
VOLTS
NEMA
STARTER
SIZE
HEATERS FOR 
OVERLOAD RELAYS
ADJUSTABLE
RELAYS
(NOTE 3)
FURNAS
(NOTE 1)
G.E.
(NOTE 2)
SET
MAX.
40
30
380
3
K78
L866B
68
73
460
3
K77
L710B
56
60
575
3
K73
L520B
45
48
50
37
380
3
K86
L107C
81
87
460
3
K78
L866B
68
73
575
3
K77
L710B
56
60
60
45
380
4(1)
K89
L126C
101
108
460
4(1)
K86
L107C
83
89
575
4(1)
K78
L787B
64
69
75
55
380
4
K92
L142C
121
130
460
4(1)
K89
L126C
100
107
575
4(1)
K85
L950C
79
85
100
75
380
5(1)
K28
L100B
168
181
460
4
K92
L155C
134
144
575
4
K90
L142C
108
116
125
90
380
5
K32
L135B
207
223
460
5(1)
K29
L111B
176
189
575
5(1)
K26
L825A
140
150
150
110
380
5
-
L147B
248
267
460
5(1)
K32
L122B
206
221
575
5(1)
K28
L100B
165
177
175
130
380
6
K26
-
270
290
460
5
K33
L147B
233
250
575
5
K31
L111B
186
200
200
150
380
6
K27
-
316
340
460
5
K33
L165B
266
286
575
5
K32
L135B
213
229
Table 30 - 60 Hz  
8"  
Motors
30