Franklin 5870206300 ユーザーズマニュアル

ページ / 28
22
NOTES: 
 (A) Operating temperature is specifi ed at full output power when installed as 
described in Controller Location Selection on Page 11.
 
(B) Refer to Page 23 for detailed mounting dimensions. 
 
(C) If a pump other than the default rating is used, refer to Page 8 for 
drive confi guration.
Input from
Power Source
(single-phase)
Voltage
190-260 VAC
Frequency
50/60 Hz
Current (max)
36 Amps (RMS)
Power Factor
1.0 (constant)
Power (idle)
65 Watts
Power (max)
7200 Watts
Output to Motor
(three-phase)
Voltage
Adjusts with Frequency
Frequency Range
30-80 Hz (3 Hp pump)
30-60 Hz (5 Hp pump)
Current (max)
17.8 Amps (RMS, each phase)
Pressure Setting
Factory preset
50 psi
Adjustment range
25-80 psi
Operating 
(A)
Conditions
NEMA 4 (indoor/outdoor)
Model 5870206300
Temperature (at 230 VAC 
input)
-13 to 125°F
(-25 to 51°C)
Relative Humidity
0-100%, non-condensing or 
condensing
Controller Size 
(B)
(approximate)
Outer dimensions
14¾” H × 15¾” W × 8¾” D
Weight
34 lbs (15.5kg)
For Use With 
(C)
Pump (60Hz)
3.0 Hp (default) 
5.0 Hp
Motor (3-phase)
234317- series (5.0 Hp) 
Specifi cations