Sony 3-270-589-12 (1) ユーザーズマニュアル

ページ / 135
48
Recording
  
Ch
apt
er 3  Rec
o
rdi
ng and
 P
la
y
bac
k
To cancel the user bits setting
Press the MENU button.
4
Press the SET button.
The message “NOW SAVING...” appears, and the 
user bits set in step 3 are displayed.
To record timecode that follows 
sequentially upon the last recorded 
timecode (Internal Regen)
You can record timecode so that it is continuous from one 
clip to the next on the disc.
Set TCG on page P2 of the function menu to “INT”, and 
TC MODE to “REGEN”. When this setting is in force, the 
unit reads the timecode of the last frame of the last 
recorded clip on the disc before starting to record, and 
internally generates timecode that follows upon the 
recorded timecode.
In this case, the setting of DF/NDF on page P2 of the 
function menu is ignored. New timecode is recorded in the 
drop-frame mode of the last recorded timecode on the disc.
To record with the internal timecode 
generator synchronized to external 
timecode (External Regen)
Use this method to synchronize the timecode generators of 
a number of recorders, to record the playback timecode of 
external VTRs, or to record while maintaining 
synchronization between the source video and timecode.
Use either of the following procedures according to the 
type of external timecode.
Synchronizing with timecode input to the TIME 
CODE IN connector
1
Connect the timecode output of an external device to 
the TIME CODE IN connector, and input a reference 
video signal to the REF VIDEO INPUT connector.
2
Make the following settings on page P2 of the function 
menu.
• Set TCG to “EXT”.
• Set TC MODE to “REGEN”.
• Set TC/VITC to “TC”.
Synchronizing with multiplexed LTC input to the 
HDSDI INPUT connector
1
Connect an HDSDI signal containing multiplexed 
LTC to the HDSDI INPUT connector, and input a 
reference video signal to the REF VIDEO INPUT 
connector.
2
Make the following settings on page P2 of the function 
menu.
• Set TCG to “SDI”.
• Set TC MODE to “REGEN”.
• Set TC/VITC to “TC”.
Synchronizing with multiplexed VITC input to the 
SD SDI INPUT or COMPOSITE INPUT connector 
(when the PDBK-104 is installed)
1
Connect a video signal containing multiplexed VITC 
to the SD SDI INPUT or COMPOSITE INPUT 
connector.
2
Make the following settings on page P2 of the function 
menu.
• Set TCG to “EXT”.
• Set TC MODE to “REGEN”.
• Set TC/VITC to “VITC”.
Synchronizing with multiplexed SMPTE RP188 
LTC input to the SD SDI INPUT connector (when 
the PDBK-104 is installed)
1
Connect a video signal containing multiplexed 
SMPTE RP188 LTC to the SD SDI INPUT connector.
2
Make the following settings on page P2 of the function 
menu.
• Set TCG to “SDI”.
• Set TC MODE to “REGEN”.
• Set TC/VITC to “TC”.
Executing either of these procedures starts the internal 
timecode generator running in synchronization with the 
external timecode generator.
Once the internal timecode generator is synchronized with 
the external timecode generator, the internal timecode 
generator continues to run even if the external timecode 
generator connection is removed.
The timecode advance mode is set automatically to Free 
Run. The frame count mode (for system frequency 60I/30P 
only) is set to the same mode as the external timecode 
signal (drop-frame or non-drop-frame).
To check the synchronization to the external 
signal
Press the STOP button to stop this unit, then press the REC 
button.
Check that the timecode value shown in the time data 
display coincides with the external timecode value.