Kohler 8002A ユーザーズマニュアル

ページ / 7
2
1067580-AN2-D   14/11/11
DIMENSIONS
8003A
8002A
G 1/2"
124 mm
89 mm
79 mm Min Clearance
67 mm
60 mm
Center of 
Water Inlet
All information is based on the latest product information available at the time 
of publication. Kohler Co. reserves the right to make changes in product 
characteristics, packaging, or availability at any time without notice. 
Please leave these instructions for the consumer.
NOTES:
1. Flush the water supply pipes thoroughly to remove any debris.
2. An in line water filter must be used with this product.
3. Inspect the supply pipes for damage. Replace as necessary.
4. Observe local plumbing codes.
5. The recommended working pressure for the shower head is 150KPa to 
    500KPa.  If the pressure exceeds 500KPa a pressure reducer is required.
6. Maximum water and environmental temperature for the shower head is 
60C. Note: If a heater is present, make sure to keep it away from the shower 
head as otherwise the environmental temperature may exceed 60C.
5IJTQSPEVDUNBZOPUCFTVJUBCMFGPSVTFXJUIDFSUBJOHSBWJUZGFEXBUFS
IFBUFSTPSMPXVOFRVBMQSFTTVSFTVQQMZOFUXPSLT
"MMJOTUBMMBUJPOTTIPVMEDPNQMZXJUISFMFWFOUSFRVJSFNFOUTPG"4/;4
and AS/NZS 6400.
BEFORE YOU BEGIN
SPECIFICATION
Pressures
                     For multiple outlets an operating pressure of 3.0 bar or greater is
recommended to ensure optimum performance. 
Plumbing Connections
                                          (Hot) and Cold (C) inlets must be connected to the 
correct inlet supplies.
Building in Depth
                                  Minimum building in depth is 79 mm. It is recommended that 
a minimum stud wall cavity of 100 mm is provided to ease installation.