           PROBLEM                    
                       POSSIBLE CAUSE                                                                                      CORRECTIVE ACTION
         Does not flush 
a.  Water supply valve closed. 
a.  Open valve and allow water to fill tank.
 
b.  Supply line blocked. 
b.  Shut off water supply, disconnect supply line, and inspect
 
 
 
     all gaskets and washers. Reassemble. Also, see Fluidmaster
 
 
 
     maintenance (see step 12).
 
c.  Flush valve chain too loose or disconnected. 
c.  Readjust chain length as required.
 
d.  Sand or debris lodged in water control. 
d.  Shut off water supply. Remove cap and clean per Step 12.
 
 
 
  Poor or  sluggish flush 
a.  Bowl water level too low. 
a.  Check that refill tube is connected to water control and
 
 
 
     inserted into tank overflow without being kinked or damaged.
 
b.  Supply valve partly closed. 
b.  Open supply valve fully. Be sure that proper supply tube size is used.
 
c.  Partially clogged trapway and/or drain pipe and/or vent. 
c.  Remove obstruction. Consult a plumber if necessary.
 
d.  Supply pressure too low. 
d.  Normal supply pressure must be at least 20 psi.
          Toilet leaks 
a.  Poor supply line connection.  
a.  Review Step 8 of installation procedure.
 
b.  Poor bowl to tank/floor connection. 
b.  Review Step 4 through 6 of installation procedure.
  Toilet does not shut off 
a.  Flush valve chain too tight, holding flush valve open. 
a.  Readjust chain length as needed. Review step 9.
 
b.  Flush valve seat and/or flapper worn or deformed. 
b.  Replace flapper/flush valve assembly, as needed.
 
c.  Sand or debris lodged in water control.  
c.  Shut off water supply. Remove cap and clean per Step 12.
-   4   -
In the United States:
American Standard Brands
P.O. Box 6820
Piscataway, New Jersey 08855
Attention: Director of Consumer Affairs
For residents of the United States, warranty 
information may also be obtained by calling 
the following toll free number: (800) 442-1902
www.americanstandard-us.com
In Canada:
AS Canada ULC
2480 Stanfield Rd.
Mississauga, Ontario 
Canada L4Y 1S2
Toll Free:  (800) 387-0369
www.americanstandard.ca
In Mexico:
Customer Service Manager 
AS Maquila, S.A. de C.V.
Via Morelos #330
Col. Santa Clara
Ecatepec 55540 Edo. Mexico
www.americanstandard.com.mx
 
• Make sure water supply is
  off. Remove valve TOP by
  lifting arm and rotating top
  and arm 1/8 turn
  counterclockwise, pressing
  down slightly on cap.
IMPORTANT: Always 
clear sand and rust from 
system.
• While holding a
  container over the
  uncapped VALVE to
  prevent splashing, turn
  water supply on and off
  a few times. Leave
  water supply off.
• Replace TOP by engaging
  lugs and rotating 1/8 turn
  clockwise. MAKE
  CERTAIN TIP IS TURNED
  TO THE LOCKED
  POSITION. VALVE MAY
  NOT TURN ON IF TOP IS
  NOT FULLY TURNED TO
  THE LOCKED POSITION.
For troubleshooting information please contact:
TROUBLESHOOTING
IF FILL VALVE SHUTS OFF BUT CONTINUES TO LEAK 
SLOWLY, 
repeat Step 12.
IF FILL VALVE TURNS OFF AND ON DURING PERIODS OF 
NON-USE, 
it is a signal you are wasting water because:
• The end of the refill tube is inserted into overflow pipe, below
   water level in tank. Attach refill tube to overflow pipe using "S"
   clip provided.
• The flush valve is leaking because it's worn, dirty or misaligned
   with tank ball or flapper (replace with a new flapper).
IF FILL VALVE WON'T TURN ON OR SHUT OFF or REFILL 
OF TANK WATER IS SLOW after valve has been in use for 
some time, 
Fluidmaster Model 242 Replacement Seal may be 
needed.
Go to our website at www.fluidmaster.com for more 
solutions to toilet problems.
©  2001 Fluidmaster, Inc.
®  Registered trademark of Fluidmaster, Inc.
Always use quality Fluidmaster repair parts when maintaining your Fluidmaster products. Fluidmaster 
shall not be responsible or liable for any damages caused by products used with Fluidmaster valves 
that were not manufactured by Fluidmaster, Inc.
30800 Rancho Viejo Road
San Juan Capistrano, CA 92675
(949) 728-2000  (800) 631-2011
www.fluidmaster.com
LEVER LE
BRAS EN
PREMIER