[29] LOC 1
Pressing this key will locate the tape to the first mem-
ory location (set with this key in shifted mode). If the 
tape is playing when this key is pressed, the tape will 
resume playing when the location is reached, other-
wise it will stop.
When the key is pressed, the value stored in the first 
location memory will flash on the right side of the 
display (frames, program numbers and margin will 
disappear while the tape is locating, and be restored 
once location is complete).
If a pre-roll time has been set in the menu, pressing 
this key will locate to the memory location minus the 
pre-roll time.
[30] LOC 2
This key functions in exactly the same way as
LOC 1 
[29]
 above, except that the second location memory 
is used rather than the first.
[31] SINGLE PLAY
The single play mode, when active, will play only 
one program , i.e. when the next START ID is 
encountered, playback will stop. When single play 
mode is active, the display will show 
SINGLE 
PLAY
.
[32] SHIFT
This key is a latching key. When active, the indicator 
beside and above the key lights, and the command 
keys take on their shifted functions, as indicated by 
the blue captions above them.
See 4, "Advanced functions" for details of these 
shifted functions.
2.5 Rear panel
[33] DIGITAL (AES/EBU) INPUT/OUTPUT
These XLR connectors, wired in accordance with the 
AES/EBU standard, provide digital audio input and 
output facilities with the data being output in either 
AES/EBU or SPDIF format (as selected in 3.6, "Dig-
ital output format"). The format of data received 
(AES/EBU or SPDIF) is automatically detected.
[34] DIGITAL COAXIAL
These RCA connectors provide digital audio input 
and output facilities with the data being output in 
either AES/EBU or SPDIF format (as selected in 3.6, 
"Digital output format"). The bit length is set using 
the menu system (see 3.7, "Digital out word length"). 
The format of data received (AES/EBU or SPDIF) is 
automatically detected.
[35] WORD IN and THRU (AUTO TERM)
These BNC connectors provide an input for an exter-
nal word clock (selected using the 
CLOCK
 switch 
[4]
 set to the 
WORD
 position) at the 
IN
 connector, 
which is re-transmitted from the 
THRU
 connector. 
There is no need to provide any termination for the 
THRU
 connector if no connection is made to it.
[36] CONTROL I/O
This 15-pin ’D’-sub connector is used for connection 
to a suitably-equipped controller.
As well as the mode described in the table below, this 
connector can also be used as a serial connector. 
Please contact your TASCAM distributor for details 
of this facility.
The pinouts of this connector are given below:
Pin 
number
Signal
Direction
Function
1
STOP
IN
External com-
mand reception; 
active when low 
(at ground poten-
tial for 30 ms or 
more)
2
FWD PLAY
IN
3
F.FWD
IN
4
REW
IN
5
PAUSE
IN
6
REC PLAY
IN
7
SERIAL
IN
8
Ground
9
FWD PLAY 
TALLY
OUT
Transmit trans-
port status indica-
tion signals in 
open collector 
(maximum allow-
able voltage 15 V 
and maximum 
allowable current 
80 mA)
10
F.FWD TALLY
OUT
11
REW TALLY
OUT
12
STOP TALLY
OUT
13
REC/PLAY 
TALLY
OUT
14
PAUSE TALLY
OUT
15
TAPE END 
TALLY
a
a. See 3.14, "End tally signal"
OUT