Tape Drive Installation 
10 
Tandberg LTO HH Installation and User Manual 
3.9.2  SCSI-bus Termination – Internal Tape Drives 
The  SCSI-bus  cable  must  be  terminated  in  both  ends  according  to  SCSI  specifications.  If  the  tape 
drive  is  the  last  device  on  the  bus,  the  bus  must  be  terminated  within  10  cm  of  the  tape  drive 
connection.  
 
Figure 3.6  Internal SCSI cable 
Tandberg  LTO  HH  tape  drives  have  a  combined  SCSI-LVD/SE  interface  embedded.  The  PC-98 
Specification specifies that the termination of the SCSI-bus system is a part of the SCSI-cable and not 
a part of the SCSI-device. 
For  internal  devices,  a  SCSI-cable  with  an  integrated  terminator  or  a  separate  terminator  applied  to 
the end connector of the cable, 10 cm from the last device must be used.  
3.9.3  SCSI-bus Termination – External Tape Drives 
If the Tape drive is the only device on the external SCSI-bus, it must be terminated using the external 
SCSI termination provided with the solution. 
If  other  external  device(s)  is/are  present,  the  Tandberg  LTO  HH  tape  drives  can  be installed in any 
position  on  the  SCSI-bus.  The  Tandberg  LTO HH tapes drive must be terminated if installed at the 
end of the SCSI-bus. See figure 3.7: 
 
Figure 3.7  Termination of external SCSI devices 
SCSI-bus 
10 cm 
Host 
 
Last SCSI Device
 
Internal Terminator Connector 
 
External terminator on 
the last device on the 
SCSI bus 
SCSI Interface adapter