Tandberg Data LTO-3 HH ユーザーズマニュアル

ページ / 40
Tandberg Data 
Troubleshooting 
Tandberg LTO HH Installation and User Manual 
27 
If a write protected, unsupported, or damaged tape cartridge is inserted in order to start the Standalone 
Diagnostics  test,  it  will  be  ejected  by  the  drive  and  the  Failure  and  Activity  LEDs  will  be  flashing 
while the Ready LED is off. The two flashing LEDs can be turned off by clicking the Eject Button. 
6.5 Media Management Reporting 1 
Media Management (MM) is a feature embedded in the Tandberg LTO HH tape drive’s firmware that 
monitors the read and write performance of the tape drive and media. Write performance information 
is written on the media header every time the media is rewound, and before the media is unloaded. 
6.5.1  Cleaning is required 
If the write performance is below a factory set re-write threshold, the Tandberg LTO HH reports that 
cleaning is required.  
Tandberg LTO HH reports that cleaning is required by setting the Clean LED to steady AMBER, and 
sending information to the backup application software using the SCSI Tape Alert reporting standard. 
 
Figure 6.1  Backup Exec reporting that the tape drive needs cleaning 
 
 
Figure 6.2  ARCserve reporting that the tape drive needs cleaning 
If the Tandberg LTO HH works normal after cleaning, both media and tape drive are good. 
6.5.2  Degraded Media 
If the write performance is still below the re-write threshold after cleaning, MM reports via the Clean 
                                                 
 
TAPE   ***TapeAlert*** The following information is for Device[0]:  
 
TAPE   E6918 The tape drive needs cleaning:  
1. If the operation has stopped eject the tape and clean the drive.  
2. If the operation has not stopped wait for it to finish and clean the 
drive. 
Check user’s manual for cleaning instructions