Mitsubishi Electronics SW1DNC-GXW2-E ユーザーズマニュアル
3 - 8
3.2.5 Setting labels
3 CREATING PROGRAM IN STRUCTURED LADDER/FBD LANGUAGE
GX Works2
3.2.5
Setting labels
Set Global Labels.
1.
Double-click "Global Label" "Global1" on the
Project view to display the Global Label Setting
screen.
Project view to display the Global Label Setting
screen.
2.
Select the "Class" from the list box on the
Global Label Setting screen.
Global Label Setting screen.
Settings
• Class: VAR_GLOBAL
3.
Directly input the "Label Name" on the Global
Label Setting screen.
Label Setting screen.
Settings
•
Label
Name: VAR1
Restrictions
● Characters available for the label name
You can enter up to 32 characters as the label name.
However, note that the following label name will cause a compile error.
However, note that the following label name will cause a compile error.
• Label name which contains space
• Label name whose first character is a number
• Label name equivalent to a device name
• Label name whose first character is a number
• Label name equivalent to a device name
For other characters unavailable for the label name, refer to the following manual.
GX Works2 Version 1 Operating Manual (Common)
(To the next page)