Atlas 240 Series ユーザーズマニュアル

ページ / 8
© 2008 Atlas Lighting Products, Inc. 
598-1094-04
Models  MLGC240B
 
MLGC240W
TEST
2 Shells
Features
•  Turns on lighting when motion is detected.
•  Automatically turns lighting off.
•  Dual Light Level.
•  Photocell keeps the lighting off during daylight hours.
•  LED indicates motion was sensed (day or night).
TEST  1 5 20
ON-TIME
Off  3  6  Dusk to
 
       Dawn
DUAL LIGHT LEVEL
Put ON-TIME switch on the sensor bottom to TEST 
and the Dual Light Level switch OFF.
OPERATION
* resets to Auto Mode at dawn.
ON-TIME
TEST 
1 5 20
... back on.
1 Second OFF 
then...
Put the ON-TIME switch in the 
1, 5, or 20 minute position.
Manual mode only works at night 
because daylight returns the sen-
sor to AUTO.
Flip the light switch off for one sec-
ond then back on to toggle between 
AUTO and MANUAL MODE.
Manual  mode  works  only  with  the 
ON-TIME switch in the 1, 5, or 20 
position.
Note:  When first turned on wait about 1 
1
/
2
 minutes for 
the circuitry to calibrate.
This package includes:
Light Control
Sensor
Cover 
Plate
Bulb 
Holders
Plastic Hanger
Rubber Plug
Gasket
6 Screws
(3 sizes included)
Mounting Strap
Mounting Bolt
2 Wire
Connectors
Requirements
•  The light control requires 120-volts AC.
•  If you want to use Manual Mode, the control must be 
wired through a switch.
• 
Some  codes  require  installation  by  a
qualified electrician.
•  This product is intended for use with the enclosed 
gasket and with a junction box marked for use in wet 
locations.
Mode:
On-Time
Works: Day Night
Test
5 Seconds
x
x
Auto
1, 5, or 20 Min
x
Manual
To Dawn*
x
Dual Light
Level
3, 6 Hr, to Dawn
x
AUTO
MANUAL MODE
GUARDIAN
 
PRO
240 S
eRieS
240-028-A