Also, it is a good practice to physically disconnect any and all valuable 
electronics from the AC mains during electrical storms, as a lightning 
strike anywhere near your home can put a tremendous surge on the AC 
mains that can easily damage any piece of electronics, no matter how well 
designed and protected. The best protection in the case of severe electrical 
storms is to simply remove the electronics from any connection with the 
power grid.
Select button
The Select button is used (along with the Mode button) when configuring 
the amplifier for either balanced or single-ended operation. It is also used 
when configuring the turn-on delay or amplifier number for an amplifier 
connected to a Classé preamplifier by the DC Trigger or CAN Bus control 
systems.
Channel status LED indicators
Each amplifier channel has two Channel LED indicators. They are used to 
indicate the use of either balanced (XLR) or single-ended (RCA) inputs for 
that channel.
These indicators are also used to indicate fault conditions in your amplifier, 
should any ever arise. If a channel’s LED indicators blink red, there is a 
problem in that particular channel. If all the Channel LEDs are blinking 
red, there may be a systemic problem that is not specific to a particular 
channel.
 
Caution! 
If  you  see  any  Channel  LED  Indicator  blinking  red,  please 
disconnect the amplifier from the AC mains immediately and 
check  that  all  external  connections  are  cleanly  made  and 
secure. If the AC mains are not easily accessible, you can press 
and  hold  the  Standby  button  for  three  seconds  to  reset  the 
amplifier. If no fault is immediately obvious, please call your 
authorized Classé dealer for assistance.
Mode button
The Mode button is used (along with the Select button) when configuring 
the amplifier for either balanced or single-ended operation. It is also 
used when configuring the turn-on delay and amplifier number of the 
amplifier when it is connected to a Classé preamplifier by the CAN Bus 