operating voltage The CP-500 preamplifier is set at the factory  for 100V, 120V, 230V, or 240V 
AC mains operation, as appropriate for the country in which it is to be sold 
(230V only in European Union countries, in compliance with CE regulations). The 
voltage setting may not be changed by the user.
Make sure that the label on the rear panel of your preamplifier indicates the 
correct AC operating voltage for your location. Attempting to operate your 
preamplifier at an incorrect voltage may damage the unit.
 
Warning: 
The voltage setting of your power amplifier may not be changed 
by  the  user. There  are  no  user-serviceable  parts  within  the 
unit. Please refer any problems to an authorized Classé service 
center.
If the AC mains voltage indicated on your preamplifier is incorrect, please 
contact your local, authorized Classé dealer or distributor.
The CP-500 can easily be powered by a normal 15-ampere AC mains line. If 
other devices are also powered from the same AC line, their additional power 
consumption should be taken into account.
The CP-500 includes protection circuitry that will prevent the preamplifier from 
operating at dangerously high or low voltages. 
•  At startup: the AC mains voltage must be within a range of 
approximately -15% to +10% of its nominal value at startup, 
or the preamplifier will not turn on. For example, a 120V unit 
requires the AC mains to be between approximately 95V–135V in 
order to turn on.
•  Over-voltage during operation: if the AC mains voltage surges 
by roughly 10% or more during operation, the preamplifier will 
enter protection mode and shut down. The Standby LED will 
flash to indicate the protection mode has been engaged.
•  Under-voltage during operation: if the AC mains voltage sags 
by 15% or more, the preamplifier will continue to play (since this 
does not present a particular danger to the unit), but note that 
it may not be able to achieve its usual standard of performance 
under these compromised conditions. The Standby LED will 
flash to indicate the condition.