register your purchase! Having found the serial number, now would be a good time to fi ll out the 
registration card. Please register your purchase so we can advise you of updates 
and other items of interest.
It will take only a minute or so. Please complete the card now, before you forget.
operating voltage Th
  e CAP-2100 integrated amplifi er is set at the factory  for 100V, 120V, 220V, 
230V, or 240V AC mains operation, as appropriate for the country in which 
it is to be sold (230V only in European Union countries, in compliance with CE 
regulations.)
 Th
  e voltage setting may not be changed by the user.
Make sure that the label on the rear panel of your power amplifi er indicates 
the correct AC operating voltage for your location. Attempting to operate your 
power amplifi er at an incorrect voltage may damage the unit.
 
Warning: 
The voltage setting of your power amplifier may not 
be changed by the user. There are no user-serviceable 
parts within the unit. Please refer any problems to an 
authorized Classé service center.
If the AC mains voltage indicated on your integrated amplifi er is incorrect, 
please contact your local, authorized Classé dealer or distributor.
Th
  e CAP-2100 can easily be powered by a normal 15-ampere AC mains line. 
If other devices are also powered from the same AC line, their additional power 
consumption should be taken into account.
Th
  e CAP-2100 includes protection circuitry that will prevent the integrated 
amplifi er from operating at dangerously high or low voltages. 
•  At startup: the AC mains voltage must be within a range of 
approximately -15% to +10% of its nominal value at startup, or 
the amplifi er will not turn on. For example, a 120V unit requires 
the AC mains to be between approximately 95V–135V in order to 
turn on.
•  Over-voltage during operation: if the AC mains voltage surges 
by roughly 10% or more during operation, the amplifi er will enter 
protection mode and shut down. Th
 e Standby LED will fl ash to 
indicate the protection mode has been engaged.
•  Under-voltage during operation: if the AC mains voltage sags by 
15% or more, the amplifi er will continue to play (since this does 
not present a particular danger to the amplifi er), but note that 
it may not be able to achieve its usual standard of performance 
under these compromised conditions. Th
 e Standby LED will fl ash 