SERVICE AND CARE ________________________________________________  
 
The chassis may be cleaned with a soft towel and Windex® (or a similar window cleaner).  Spray it on the 
cleaning cloth to moisten it, not on the component. Do not use solvents or harsh chemicals as they may 
remove the labels from the chassis. The frequency and need of cleaning will be governed by operating 
environmental conditions. Avoid letting the component become dusty or wet. A ‘feather duster’ type 
cleaner will also work well for cleaning the component.  
 
Replacing Vacuum Tubes 
If it becomes necessary to replace the tubes, the same brand as installed new should be used. A complete 
new tube kit is available from Cary Audio Design. Although useful tube life varies depending on the nature 
and degree of use, under normal home use, the 845 output tube and the 300B driver tube should last 
many years in the CAD 211 FE. The 6SL7 input tubes should last even longer.  
 
NOTE: Any current production or New Old Stock (NOS) types of 845, 6SL7 or 300B tubes will work fine in 
the CAD 211 Founder’s Edition amplifier. The voltages are fine for all available types. 
 
WARNING 
Make sure the amplifier is unplugged 30 minutes from the AC mains before replacing the 
tubes to avoid risk of shock and high heat from the 845 tube. 
 
Factory Service 
Careful consideration has been given to the design of this product to keep maintenance problems to a 
minimum.  If problems arise, refer to the trouble-shooting guide at the end of this manual. If the problem 
is not easily solved, we suggest that you contact our Customer Service Department by phone at (919) 355-
0010, 1–5 pm Eastern Standard Time, to describe your problem in detail. Do not return the component to 
the factory without a Return Authorization Number (RA) from the Customer Service Department.   
 
Cary Audio Design assumes no responsibility if the transportation company refuses to pay a damage claim 
due to your improper packing or lack of insurance should the unit be lost in shipment. We strongly 
suggest using the original packing cartons for shipping any Cary Audio Design component. 
 
Non-Warranty Repairs 
Cary Audio Design will provide repair service for its products charging on a time and expense basis. At this 
time, the standard non warranty service bench fee is $125 with all parts used for repair charged extra. This 
may change with time and is not a quote for service. Please call us at 919-355-0010 for more information 
about out of warranty service and repair fees. 
 
WARNING 
Make no attempt to put the CAD 211 FE in service outside of the cabinet or with the cabinet 
open! Contact with the high voltages found inside the unit can be fatal! Remove the AC power 
plug from the wall and allow 30 minutes for the high voltage capacitors to discharge through 
bleeder resistors before attempting to change the tubes or to clean the inside the amplifier.  
 
 