Crown Equipment XLS 202 ユーザーズマニュアル

ページ / 36
XLS Series Power Amplifiers
Operation Manual
Mode d'emploi
page 21
Amplificateurs de puissance
Bedienungsanleitung
Leistungsendstufen
Manual de Operación
Amplificadores de potencia
4.1.3 Circuit Breaker 
The high-voltage power supplies of your Crown 
amplifier are protected by a circuit breaker. The 
breaker rating varies depending on model and sup-
ply voltage as follows:
4.1.4 Thermal Protection
The Thermal Protection circuit will activate if the 
internal heatsink temperature exceeds proper oper-
ating temperatures (194 °F, 90 °C). When the heat-
sink temperature has fallen to a safe level, this 
protection circuit will automatically be reset. Princi-
ple causes of thermal protection are: 
1) Inadequate ventilation of the equipment rack
2) Incorrect load impedance
3) Output cable short circuit
4) Blocked air vent