FRONT VIEW
This indicator lights when the power amplifier has been switched on. Causes for
the POWER-indicator not lighting are: the appliance is not connected to the mains 
network, a defective primary fuse, or the power amplifier is set to stand-by operation
(STAND-BY LED lights).
 
 
 This indicator light when the power amplifi er is in stand-by mode, which can be 
 
 
 activated from the RCM-24 or via Easy Remote. In stand-by operation only the 
 
 
 internal auxiliary power supply unit is activated. The main power supply unit is 
 
 
 separated from the mains.
The PROTECT LED lights indicating that one of the internal protection circuits 
against thermal overload, short-circuit, Back-EMF, HF-occurrence at the output, etc., 
has been activated. In that case, the output relays separate the power amps from 
the load connected to prevent the connected loudspeaker systems and the power 
amplifiers as well from being damaged. Whatever caused the fault – e.g. a short-
circuited speaker cable – 
needs to be remedied. In case of thermal overload you 
have to wait until the power amplifi er automatically regains normal operation
.
The OUT LED lights as soon as an audio signal of approximately 30dB below full 
modulation is present. The LED is dimmed when speaker cables are short-circuited 
or a protection circuit has been activated
.
The 0dB LED lights when the power amplifier is driven at its maximum. Higher input 
voltage does not result in higher peak output voltage.
This indicator lights as soon as the integrated dynamic limiter is activated and the 
power amplifier is driven at the clipping limit or generally at its maximum capacity. 
Short-term blinking is not a problem, since the internal limiter trims input levels of up 
to +21dBu down to a S/N-ratio of approximately 1%. If, on the other hand, this LED 
lights constantly, reducing the volume is recommended to prevent the loudspeaker 
systems connected from being damaged by probable overload
.
Use the 
POWER switch located in the centre of the front panel to switch the appliance’s power 
on. The soft-start function prevents current inrush peaks on the mains, which in addition prevents 
the mains line protection switch from activating during power-on operation of the power amplifier. 
The loudspeaker outputs are activated via relay switching with a delay of approximately 2 seconds 
effectively attenuating eventual power-on noise. The PROTECT LED lights during the delay time and 
the fans run at maximum speed. This is normal to confirm the immaculate operation of the protection 
circuitry. Upon power-on, all power amps with RCM-24 Module installed regain the state of operation 
prior to the last power-off.
For example: if a power amplifier had been switched off using the POWER-switch while being in Stand-
by mode, upon power-on it restarts in this exact mode.