CONTROLS
INPUT 
Electronically balanced input for the connection of high-level 
signal sources like mixing consoles or signal processors. 
Connections can be established using phone or alternatively 
XLR-type connectors. 
Caution: Preventing the occurrence of spurious noise.
Prior to connecting/disconnecting the input, set the 
level control to its counterclockwise stop.
 
OUTPUT 
This connector is connected in parallel to the input allowing 
the through connection of the input audio signal.
LEVEL
dB-scaled level control for adjusting the power amp’s overall 
amplification. To prevent distortion and clipping of pre-linked 
mixing consoles, the control should generally be set to a 
value between 0dB and +6dB. 
MODE
This  switch  allows  selecting  the  operation  mode  of  the 
M15.  The  cabinet’s  internal  active  frequency  crossover  is 
automatically  deactivated  when  set  to  FULLRANGE.  The 
loudspeaker  system  transmits  the  entire  frequency  range. 
Setting  the  switch  to  the  position  MID-HIGH  activates  an 
active frequency crossover with 124Hz crossover frequency, 
so that only the audio signal’s mid-high range is transmitted.
When  using  a  M15  in  combination  with  a  M18  subwoofer, 
selecting  MID-HIGH  is  generally  recommended,  to  ensure 
linear frequency response of the M15/M18 combination.
Using the cabinet in MID-High mode in monitoring applications 
may  be  favorable  for  attenuating  the  reproduction  of  low 
frequency signals.