Turbosound B-15/DP ユーザーズマニュアル

ページ / 4
Quickstart Guide 
NuQ series 
 
NuQ Series Quickstart Guide v1.2 - Page - 1 
Models covered by this Quickstart Guide 
NuQ-6, NuQ-8/DP, NuQ-10/DP, NuQ-12/DP, NuQ-15/DP, B-12DP, B-15/DP, B-18/DP. 
Thank you for choosing a TURBOSOUND loudspeaker product for your application.  If you would like further information 
about this or any other TURBOSOUND product, please contact us on +44 (0)1403 711447. A detailed user manual on this 
product range is available on our website at http://www.turbosound.com 
Unpacking the Loudspeaker 
After unpacking the unit please check carefully for damage. If damage is found, please notify your supplier at once. You, 
the consignee, must instigate any claim. Please retain all packaging in case of future re-shipment. 
System Requirements – Passive and Bi-amped Loudspeakers 
The NuQ-6, NuQ-8, and NuQ-10 two-way loudspeakers are passive systems and 
require only one amplifier channel for correct operation, the frequency splitting 
between the LF driver and the HF driver being accomplished by the internal 
passive crossover network built into each enclosure. They are equipped with 
two Neutrik Speakon NL4MP connectors wired in parallel, serving as both input 
and loop-out connections to additional speakers. The Speakon wiring details are 
shown at the right. The NuQ-12 and NuQ-15 two-way loudspeakers are 
switchable passive/bi-amped systems and require two amplifier channels when 
used in bi-amped mode. To avoid wasting amplifier power you should use 
heavy-duty speaker cable with a minimum wire size of 12 gauge (1.5mm²), and 
preferably 10 gauge (2.5mm²) for longer runs. Always observe the correct 
polarity as shown. 
Amplifier considerations 
NuQ series speaker enclosures should be driven by high quality power amplifiers designed for true professional use. 
Amplifiers should be capable of delivering long term broadband power equal to the loudspeaker’s program power rating 
at its stated nominal impedance. The use of under-powered amplifiers must be avoided as heavily clipped signals can 
cause permanent loudspeaker damage.  
Model 
NuQ-6 NuQ-8 NuQ-10 NuQ-12 
NuQ-15 
B-15 
B-18 
Impedance 
8 
8 
8 Passive: 
8  
LF: 8, HF: 6 
Passive: 8 
LF: 8, HF: 6 
8 
8 
 
 
RECOMMENDED AMPLIFIER POWER RATING 
The amplifier’s rated r.m.s. continuous power output (20Hz – 20kHz, each channel) 
should be equal to the loudspeaker’s program power handling at its nominal impedance. 
 
System Controllers and Bi-amplified systems 
NuQ systems must be used with Turbosound LMS-D24 or LMS-D26 controllers, since these provide vital operating and 
system security features. If you do not have a controller, DO NOT USE the loudspeaker without one; please contact your 
Turbosound dealer for further details. 
 
(Pins 2+ and 2- not connected)
Passive Speakon
connections
Negative (-ve)
Positive (+ve)
1-
1+
2+
2-
Bi-amped Speakon
connections
LF Negative (-ve)
LF Positive (+ve)
HF Negative (-ve)
HF Positive (+ve)
1-
1+
2+
2-