All units are provided with right hand rotation unless otherwise 
specified.    This  means  that  cable  is  pulled  off  spool  top  left 
or  bottom  right  (spool  rotates  clockwise  to  wind  cable) 
when 
viewing spring end of reel.  See diagram on parts page.
Clock-type springs provide power for automatic cable take-up. 
Spring must be pretensioned at time of installation to insure 
that tension is applied to cable at all times.  A tension adjustment 
spanner wrench is provided with each reel. 
INSTALLATION
1.  Insure that machinery to be serviced by reel is at position 
     closest to reel.
2.  Securely mount reel in desired position using 3/8"(M10)
     bolts.  Be sure spool is aligned with cable run.
3.  Position optional cable guide, if reel is so equipped. 
4.  Connect free end of cable to junction box on machine or 
     adjust cable stop so that desired length of cable 
     extends from reel.
5.  Remove cover plate on spring housing to
 
expose
     shaft and spring hub. (See Figure 1).
6.  Insert spanner wrench into holes in spring hub (Fig 2).
     Rotate wrench counterclockwise (for standard rotation).
     Number of 360
º turns should match last digit in model 
     number on serial plate. If model number includes an “R”,
     reel is reverse rotation and wrench must be rotated 
     clockwise. (See EXPLANATION on parts list page.) 
 NOTE:  If reel is equipped with ratcheted adjustment 
wrench, follow instructions on separate sheet.
NOTE:  On reels containing more than one spring, the hubs 
are connected at the factory.  Therefore, by tightening the 
outer spring, the inside spring(s) will be tightened.
7.  Remove collector cover and connect individual supply 
     conductors to collector terminals.
Do not attempt to relieve spring tension using spanner 
wrench.  Doing so may result in personal injury.
WARNING
Some reels with large or multiple springs are equipped with 
a ratcheted adjustment wrench.  Follow separate instruc-
tions for its use.  Failure to use ratcheted wrench, on reels 
so equipped, could result in serious personal injury.
WARNING
COVER 
PLATE
SPRING 
HUB
SPRING 
HOUSING
COUNTER-
CLOCKWISE 
FOR STANDARD 
ROTATION
SPANNER 
WRENCH
Figure 1
Figure 2
CONTINUED ON BACK PAGE
INSTALLATION and MAINTENANCE INSTRUCTIONS
SHO SERIES ELECTRIC CABLE REELS
MAINTENANCE
Periodically: A. Use compressed air to clean collector assembly 
and inside of collector housing.  Inspect collector assembly for 
brush wear and pitted slip rings.
B. Inspect cable for wear and 
check mounting bolts and other 
hardware for tightness.
C. Check for broken springs by 
pulling about 2/3 cable off reel 
and observing “Broken Spring 
Indicators” on sides of spring 
canisters.  See Fig. 3.
NOTE:  Bearings and springs 
are prelubricated and require no 
periodic maintenance.
SPRING REPLACEMENT
The  unique  SAFETYCHANGE®  spring  motor  consists  of  a 
spring and hub sealed within a housing.  A replacement spring is 
supplied sealed in its housing and the old unit should be discarded 
completely.
1.  Turn off all electric power.
2.  Disconnect cable from machine junction box.
3.  Wind all cable onto reel to relieve all spring tension.
4.  Remove inspection cover from face of spring housing.
5.  Rotate spool clockwise and observe inner shaft. Shaft should  
     rotate clockwise and hub (with spring attached) should  
     
     remain stationary.
     NOTE: Do not attempt to remove spring if 
resistance is met or hub tends to rotate with shaft.  
    Continue to rotate spool and strike end of shaft several sharp  
    blows with a lead hammer or rubber mallet until shaft rotates   
    freely and hub remains stationary.  
6.  Remove (4) nuts which secure spring motor(s) to frame.
7.  Slide spring motor(s) off shaft and discard. 
     NOTE: On multi-spring reels, be sure to remove and save     
     dowel pins which connect one spring hub with another. Also           
     remove snap rings on shaft between spring housings. 
8.  Install replacement spring motor(s), pawls and pawl springs.
NOTE: Pawl springs must be located between the pawls          
and the deepest section of the shaft grooves.  Make sure that 
pawls and pawl springs are inserted  flush with ends of shaft and 
hub or they may rub against inspection cover.
9.    Tighten nuts (and extension bolts) securing spring  
      
       housing(s) to reel frame.
10.  Connect free end of cable to junction box on machine or adjust   
        cord stop so that desired length of cord extends from reel.
11.  Tension spring with spanner wrench. Refer to      
  
       
INSTALLATION  section.
12.  Replace inspection cover.
Do not attempt to remove spring from its housing. Clock-
type springs can be dangerous to handle.  Removal of 
spring from housing could result in personal injury.
WARNING
BROKEN SPRING 
INDICATORS
“IN” with 2/3 
cable off reel–
SPRING OK
“OUT” with 2/3 
cable off reel–
SPRING 
BROKEN
Figure 3
PAWL
SIDE VIEW
END VIEW
SPRING
Install 
against flat 
SPRING
HUB
(Spring not 
shown)
SHAFT 
GROOVE
SPOOL 
SHAFT
Printed in USA
Bulletin No. 052980.b
GLEASON REEL CORP.
P.O. Box 26 • 600 South Clark St.
Mayville, WI  53050
Phone 920-387-4120 • Fax 920-387-4189
Do not exceed number of turns indicated on
 serial plate.  Over-tensioning can cause a 
broken spring, sheared shaft or other damage.
CAUTION
Failure to relieve all spring tension prior to removing 
cable could result in damage to equipment or 
personal injury. Follow instructions carefully
CAUTION
CABLE REMOVAL
Use the following procedure to remove worn or damaged 
cable from reel prior to installation of new cable.
Move machine serviced by reel to a position closest to     
1. 
reel. Springs will still be under pre-tension at this point. 
Turn off all electric power.
2. 
Lock spool to prevent turning using wither a spool lock 
3. 
mechanism or by tying off.
Disconnect cable from machine junction box.
4. 
Grip spool by hand and 
5. 
carefully release spool lock or 
tie. Slowly unwind remaining tension.
Again lock or tie spool to prevent rotation.
6. 
Remove cable from spool. Loosen U-bolt and water-tight 
7. 
connector and disconnect conductors from slip ring.
Install new cable following instruction at right. 
8. 
CABLE INSTALLATION
Use the following procedure to replace cable or if reel was 
ordered without cable. Refer to CABLE INSTALLATION 
REFERENCE DRAWING, below.
Unspool new cable from shipping spool and lay out to 
1. 
eliminate twist.
NOTE: This step is not essential, but will aid in winding 
operation of the reel and prolong cable life.
Feed one end of the cable through water-tight connector 
2. 
on the main shaft inside the spool and into the slip ring 
side (see drawing below).
NOTE: This may require that jacket of cable be stripped to 
allow conductors to pass through shaft.
Connect individual conductors to appropriate rings on 
3. 
collector using crimp fitting or similar connection method.
Tighten water-tight connector and U-bolt provided on 
4. 
drum wrapper segments. 
Do not over-tighten.
Wind the cable onto the reel spool by hand rotation spool 
5. 
in direction it tuns free of spring tension. 
Connect free end of cable to machine junction box.
6. 
Pretension reel and complete installation as previously 
7. 
described.
COLLECTOR REPLACEMENT
Turn off all power to reel.
1. 
Remove collector cover and gasket.
2. 
Disconnect electric leads to and from collector. 
3. 
Remove drive stud bolt from bearing housing.
4. 
Remove pipe plug from hole in side of housing. Insert 
5. 
long 1/8" Allen wrench through hold and loosen two set 
screws in collector locking collar. Set screws are at 90° to 
one another.
NOTE: Older reels may have lock screws which must be 
removed to reach set screws holding collector to shaft.
Slide collector off shaft.
6. 
Install new collector by reversing above steps. 
7. 
Collector
Cable
(Input)
Cable
(Output)
Reel
Shaft
Connect leads 
to collector
Frame/Gear Case
Spool
NOTE:
Strip cable to inside of gland 
if required. Wrap leads with 
electrical tape thru shaft.
Cable Gland
Thread gland into shaft. 
Thread cable thru gland and 
shaft. Tighten gland cover to 
secure cable. 
CABLE INSTALLATION REFERENCE DRAWING