JBL Professional 47HC ユーザーズマニュアル

ページ / 12
The  installation  of  the  Control  Contractor  40  Series  in-
ceiling loudspeakers can be accomplished, if necessary, 
without requiring access above the ceiling.  Bracketry for 
use with either suspended ceilings or sheetrock ceilings is 
included  (see  below  for  additional  details  on  the  Control 
42C
).  The  loudspeaker  is  held  securely  in  place  via 
mounting ears which lock into place.  Inputs are attached 
to a removable locking connector (included) which can be 
prewired  before  installing  the  loudspeaker  for  ultra-fast 
snap-on installation.
The lightweight Control 42C (0.7 kg / 1.6 lbs) includes a 
C-
ring  but  does  NOT  include  tile  rails.    In  the  event  that 
tile  rails  are  required,  they  are  available  as  an  optional 
accessory (MTC-Rail). 
OPTIONAL PRE-INSTALLATION BRACKETS 
IN  MOST  CASES,  NO  BRACKETS  OTHER  THAN 
THE  ONES  INCLUDED  WITH  YOUR  SPEAKER  ARE 
REQUIRED.    Everything  needed  for  most  installations 
of  these  loudspeakers  is  provided  with  your  Control 
Contractor 40 Series in-ceiling loudspeakers.
Installation  into  sheet  rock  (typically  gypsum  board)  can 
be  facilitated  by  the  use  of  JBL’s  optional  preinstallation 
brackets  before  the  sheetrock  is  installed.    The 
preinstallation bracket provides a bracket to which wiring 
can  be  tied  behind  the  sheetrock  and  it  can  function  as 
a  cutout  template  when  many  cutouts  are  to  be  made 
in  a  production-line  style  installation.   Two  types  of  pre-
installation  brackets  are  available  from  JBL  Professional 
as optional accessories:
1)  The  optional  NEW-CONSTRUCTION  BRACKETS 
(available options and listed below) are made of flat sheet 
metal, with wings to attach to the building structure.  Holes 
are drilled for nails or screws at 16 inches (406 mm) and 
24  inches  (610  mm)  on-center.    Additional  holes  can  be 
drilled by the installer at other spacings up to a maximum 
of 24-3/4 inches (630 mm) apart.  Sheet rock installs over 
the bracket, and the bracket provides a template for blind 
cutout  of  the  hole  in  the  sheet  rock.   The  sheet  rock  is 
typically  cut  with  a  router-type  cutting  tool,  using  the 
bracket ring as a cutout guide.
Available New Construction Brackets
MTC-42NC for the Control 42C
MTC-47NC for the Control 47C/T & Control 47LP
MTC-19NC for the Control 47HC & Control 40 CS/T
2) The optional MUD-RING BRACKET (available options 
and  listed  below)  contains  a  circular  offset,  forming  an 
edge  guide  for  sheet  rock  plastering.    The  bracket  has 
wings that attach to the building structure.  Sheet rock is 
typically precut, then the sheet rock hole can be plastered 
(or “mudded”) up to the ring to create a seamless cutout.
Available Mud-Ring Brackets
MTC-42MR for the Control 42C
MTC-47MR for the Control 47C/T & Control 47LP
MTC-19MR for the Control 47HC & Control 40 CS/T
USING INCLUDED C-BRACKET WITH SHEETROCK
For many installations, the INCLUDED C-shaped backing 
plate  provides  adequate  reinforcement  to  the  ceiling 
material,  spreading  out  the  clamping  force  from  the  tab 
clamps.  
CUTOUT SIZES
Packaged with the speakers are cardboard cutout templates 
for scribing the cutout hole onto your ceiling surface. The 
cutout size diameters for the Control Contractor 40 Series 
are listed on the following page. 
CONTROL 40 SERIES PREPARATION
Optional New-Construction 
Bracket
Optional Mud 
Ring Bracket
3