Meyer Sound MSL-4 ユーザーズマニュアル

ページ / 17
4
Introduction
The MSL-4 self-powered loudspeaker system is ideal for large 
venues requiring long throw distances and precise coverage, 
but can also be used effectively in smaller applications. Its high-
Q (narrow coverage) horn has a consistent beam width across 
its entire frequency range, enabling efficient array design that 
maximizes coverage and SPL for a given array size. 
The  MSL-4  contains  independent  amplifier  and  control 
electronics for one 12” low frequency cone driver (in a horn-
loaded vented enclosure) and one high frequency horn driver 
(2” throat, 4” diaphragm) in a compact trapezoidal cabinet. This 
integrated design provides excellent performance, durability, 
and  reliability,  eliminates  amplifier  racks,  and  simplifies 
setup and installation.
The MSL-4 matches well with the Meyer Sound DS-4 self-pow-
ered mid/bass loudspeaker, the PSW-2 and 650-P self-powered 
subwoofers, and also performs efficiently with the PSW-4. The 
MSL-4 can be used as a full-range or mid-hi speaker and has 
the following acoustical specifications:
Frequency Response  
±4 dB 65 Hz – 18 kHz
Phase Response 
±30° 450 Hz – 10 kHz 
Coverage 
40° H x 35° V
Dynamic Range  
> 110 dB 
The  MSL-4  can  be  equipped  to  operate  with  the  Remote 
Monitoring System
 (RMS) interface network and software 
application. RMS displays signal and power levels, driver and 
cooling fan status, limiter activity, and amplifier temperature 
for all speakers in the network on a Windows-based PC. Contact 
Meyer Sound for more information about RMS.
AC Power
When AC power is applied to the MSL-4, the Intelligent AC™  
supply automatically selects the correct operating voltage, al-
lowing  the  MSL-4  to  be  used  in  the  US,  Europe,  or  Japan 
without manually setting a voltage switch. The Intelligent AC  
power supply also protects the MSL-4 by performing surge 
suppression for high voltage transients (up to 275V), min-
imizing inrush current, and filtering EMI. The MSL-4 uses a 
NEMA L6-20P or IEC 309 male power inlet and satisfies UL, 
CSA, and EC safety standards. 
NOTE: Continuous voltages higher than 275V may damage 
the unit! 
Voltage Requirements
The MSL-4 operates safely and without audio discontinuity if 
the AC voltage stays within the ranges 85–134V or 165–264V, 
at 50 or 60Hz. Immediately after applying AC power, the green 
Active LED on the user panel illuminates and the proper operat-
ing voltage is automatically selected, but the system is muted. 
During the next three seconds, the primary fan turns on, the 
main power supply slowly ramps on, and the system is enabled 
to pass audio signals. 
TROUBLESHOOTING  NOTE:  If  the Active  LED  does  not 
illuminate or the system does not respond to audio input after 
ten seconds, remove AC power to avoid possible damage to 
the unit. Experienced electronics technicians with access to a 
test bench can verify proper operation for the power supply and 
amplifier system with The Meyer Sound Self-Powered Series MP-2 
and MP-4 Field Verification Procedure (part # 17.022.066.01; 
contact Meyer Sound to receive this document). All other users 
should  contact  Meyer  Sound  or  an  authorized  Meyer  Sound 
service center.
If the voltage decreases below the lower bound of either op-
erating range (known as a brown-out period), the supply uses 
current from its storage circuits and continues to function briefly. 
The unit turns off if the voltage does not increase above the 
threshold before the storage circuits are depleted. The length 
of time that the MSL-4 continues to operate during brown-out 
depends on how low the voltage drops and the audio source 
level during this period. 
If the voltage fluctuates within either operating range, automatic 
tap selection stabilizes the internal operating voltage. This tap 
selection is instantaneous and there are no audible artifacts. If 
the voltage increases above the upper bound of either range, 
the power supply turns off rapidly, preventing damage to the 
unit. 
If the MSL-4 shuts down due to either low or high voltage, the 
power supply automatically turns on after three seconds if the 
voltage has returned to either normal operating range. If the 
MSL-4 does not turn back on after ten seconds, remove AC power 
and refer to the TROUBLESHOOTING NOTE above.
Current Requirements
The MSL-4 presents a dynamic load to the AC mains which 
causes the amount of current to fluctuate between quiet and 
loud operating levels. Since different types of cables and circuit 
breakers heat up (and trip) at varying rates, it is essential to un-
derstand the types of current ratings and how they correspond 
to circuit breaker and cable specifications. 
The  maximum  continuous  RMS  current  is  the  maximum 
RMS current over a duration of at least 10 seconds. It is used 
to calculate the temperature increase in cables, which is used to 
select cables that conform to electrical code standards. It is also