Hifionics HFI55.4 ユーザーズマニュアル

ページ / 15
AMPLIFIER FEATURE DESCRIPTIONS
HFi AMPLIFIERS:
! Each model is capable of 4 & 2-Ohms stereo per channel, or 4-Ohms mono bridged operation 
! All Hifonics amplifiers feature a comprehensive diagnostic system, with speaker lead short circuit, 
and amplifier DC faults indicated by the red “PROTECT” LED.
except the mono amps which are capable of 4, 2 and 1-Ohm loads.
 CAUTION: DO NOT OPERATE ANY AMPLIFIER BELOW THE INTENDED IMPEDANCE. YOU 
 Tri-Mode operation with any stereo pair of amplifier channels is possible, as with all bridgeable 
!
!
WILL CAUSE DAMAGE TO THE AMPLIFIER THAT WILL NOT BE COVERED UNDER THE 
amplifiers.
! The input sensitivities for rated output powers are variable from 0.2 volts to 6 volts.
WARRANTY PRINTED IN THE BACK OF THE MANUAL. 2 & 4 Channel amps are capable of 4 
! All crossovers are fully variable in their respective ranges.
and 2-Ohms wired stereo and 4-Ohms wired mono bridged. The mono amps are capable of 4, 2 
! Crossover filters are 12dB/Octave.
and 1-Ohm.
! A POWER  LED indicates the powered up and turned on condition.
2
-The LINE INPUT signal is routed directly to the LINE OUT RCA jacks, regardless of the X-OVER 
setting simplifying daisy chaining of amplifiers.
-SUBSONIC: Allows you to adjust the crossover filter from 15Hz to 35Hz.
-LPF: Allows yo to adjust the LOW PASS crossover filter from 30Hz to 250Hz.
LEVEL:  Adjusts the input sensitivity from 0.2 volts to 6 volts.
BASS EQ: The Bass EQ is adjustable from 0db to 10dB.
REMOTE: This is the input jack for the remote Level control.
LINE INPUT: The line input accepts unbalanced (RCA) inputs from 0.2V to 6V.
LINE OUTPUT: The line output passes through signal from the line inputs which allows you to daisy 
chain multiple amplifiers from one signal.
The mono amps are capable of 4, 2 & 1-Ohm  loads.
Operating the amp below 1-Ohm can cause damage to the 
amp not covered in the warranty.
HFi1000D / HFi1500D / HFi2000D / HFi2500D MONO BLOCK AMPLIFIERS
OUTPUT     INPUT
L                            L
R                            R
POWER
PROTECT
6V  0.2V                 0dB  10dB                                               15Hz  35Hz                 30Hz  250Hz
LEVEL   BASS EQ   REMOTE   SUBSONIC  LOW PASS
The 4 channel amps have the same features as the 2 channel models accept that there are 2 sets of 
controls.
1 set for channels 1 & 2 and 1 set for channels 3 & 4.
In addition, the 4 channel models have a Mode switch which allows you to select 2, 3 or 4 channel 
operation. Switch to 2 channel if you only have 1 set of RCA’s in CH 1/2 and the unit will automatically
supply signal to channels 3/4. Select 3 channel when you only have RCA’s in CH 1/2 but plan to run
channels 3/4 bridged. Select 4 channel if you are providing RCA’s to channels 1/2 and 3/4.
The X-OVER slide switch selects the internal crossover functions:
-The input signal is routed directly to the LINE OUT RCA jacks, regardless of the X-OVER setting 
simplifying daisy chaining of amplifiers.
-HPF: Selects the built in HIGH PASS filter, variable from 60 Hz to 12kHz.
-FULL: Bypasses all crossovers for full frequency range operation.
-LPF: Selects the built in LOW PASS , variable from 30 Hz to 250Hz.
MODE: The mode switch allows you to choose Stereo for full range 2 channel operation or MONO 
for bridging operation
HIGH INPUT: If your radio/CD player does not have unbalanced (RCA) outputs, you can use the 
HIGH level (wire) inputs.
LINE INPUT: The line input accepts unbalanced (RCA) inputs from 0.2V to 6V.
LINE OUTPUT: The line output passes through signal from the line inputs which allows you to daisy 
chain multiple amplifiers from one signal.
Note that the LOW PASS signal is MONO.
-In the LPF position, the HIGH PASS filter acts as a subsonic 
filter.
-When the LPF mode is selected, a 0 to +12dB, at 45Hz, BASS 
-EQ is also switched in.
HFi55.4 / HFi100.4 4-CHANNEL AMPLIFIERS
LINE OUT
CH3/4       CH1/2
L                            L
R                            R
6V  0.2V                 0dB  12dB       FULL  LPF HPF      60Hz   12KHz       30Hz  250Hz 
LEVEL   BASS EQ   X-OVER       HPF          LPF
6V  0.2V                 0dB  12dB       FULL  LPF HPF      60Hz   12KHz       30Hz  250Hz               2    3     4
LEVEL   BASS EQ   X-OVER       HPF          LPF          MODE
POWER
PROTECT
The X-OVER slide switch selects the internal crossover functions:
-The input signal is routed directly to the LINE OUT RCA jacks, regardless of the X-OVER setting 
simplifying daisy chaining of amplifiers.
-HPF: Selects the built in HIGH PASS filter, variable from 60 Hz to 12kHz.
-FULL: Bypasses all crossovers for full frequency range operation.
-LPF: Selects the built in LOW PASS , variable from 30 Hz to 250Hz.
MODE: The mode switch allows you to choose Stereo for full range 2 channel operation or MONO 
for bridging operation
HIGH INPUT: If your radio/CD player does not have unbalanced (RCA) outputs, you can use the 
HIGH level (wire) inputs.
LINE INPUT: The line input accepts unbalanced (RCA) inputs from 0.2V to 6V.
LINE OUTPUT: The line output passes through signal from the line inputs which allows you to daisy 
chain multiple amplifiers from one signal.
Note that the LOW PASS signal is MONO.
-In the LPF position, the HIGH PASS filter acts as a subsonic 
filter.
-When the LPF mode is selected, a 0 to +12dB, at 45Hz, BASS 
-EQ is also switched in.
HFi100.2 2-CHANNEL AMPLIFIERS
OUTPUT   INPUT
L                            L
R                            R
6V  0.2V                 0dB  12dB       FULL  LPF HPF      60Hz   12KHz       30Hz  250Hz        MONO    STEREO
LEVEL   BASS EQ   X-OVER       HPF          LPF          MODE
POWER
PROTECT