Mitsubishi Electronics MR-J2S- A ユーザーズマニュアル

ページ / 385
15 -  45
15. ABSOLUTE POSITION DETECTION SYSTEM
M8000
K1
K4M100
K25
K0
TO
M200
K1
K3M200
K28
K0
FROM
K1
D106
K26
K0
DFROM
M108
RST
END
6
6
FX2     1PG
Transmission of control signals
1PG     FX2 
Transmission of status
1PG     FX2 
Transmission of present
position D106, D107
1PG 
Resetting start command
(Continued from preceding page)
Normally
ON
(d) Data set type home position return
After jogging the machine to the position where the home position (e.g.500) is to be set, choose the
home position return mode set the home position with the home position return start (PBON).
After switching power on, rotate the servo motor more than 1 revolution before starting home
position return.
Do not turn ON the clear (CR) (Y5) for an operation other than home position return. Turning it
ON in other circumstances will cause position shift.
Y1
X0
X14
M70
M71
T210
M70
PLS
M71
D24
K500
DMOVP
K1
D24
K13
K0
DTOP
K1
D24
K26
K0
DTOP
T210
M71
SET
K10
M71
RST
Y5
Clear (CR) ON timer request
Clear (CR) 100ms ON timer
Setting data set type home position return request
Resetting data set type home position return request
Clear (CR) ON
Setting X-axis home position address "500"
in the data register
Changing X-axis home position address
Changing X-axis present position data
ABS transfer
mode
Positioning
completion
Home position
return start PB
Clear signal ON
timer request
Date set type home position return request
Clear signal 100ms ON timer
Data set type
home position
return request