4 -  16 
4. OPERATION 
 
(a) Absolute value command system 
1) Positioning in single direction 
The position data (addresses) of the midway point tables are not used for positioning and speed 
is changed continuously to move to the set address in the last point table. 
The operation example given below assumes that the set values are as indicated in the following 
table. 
Point table 
No. 
Position data 
[ 10
STM
m] 
Servo motor 
speed [r/min] 
Acceleration time constant 
[ms] 
Deceleration time constant 
[ms] 
Dwell [ms] 
(Note 1) 
Auxiliary 
function 
1 5.00 3000 
100 
150 
0 1 
2 10.00 2000 
Invalid 
Invalid 
0  1 
3 15.00 1000 
Invalid 
Invalid 
(Note 2)
 
Note 1. Always set "0". 
         2. Always set "0" to the auxiliary function of the last point table among the consecutive point tables. 
 
Acceleration time constant
of point table No. 1 (100)
Deceleration time constant
of point table No. 1 (150)
Speed
(3000)
Speed (1000)
Speed
(2000)
Position address
Selected point table No.
Forward rotation start
(ST1)
Servo motor speed
Forward
rotation
ON
OFF
0
0
5.00
10.00
15.00
1
1
Point No. out put
(PT0 to PT4)