8. GENERAL GAIN ADJUSTMENT 
 
(c) Adjustment description  
1) Speed control gain 2 (parameter No. 37) 
This parameter determines the response level of the speed control loop. Increasing this value 
enhances response but a too high value will make the mechanical system liable to vibrate. The 
actual response frequency of the speed loop is as indicated in the following expression. 
Speed loop response 
frequency(Hz)
Speed control gain 2 setting
 (1   ratio of load inertia moment to servo motor inertia moment) 2  
2) Speed integral compensation (VIC: parameter No. 38) 
To eliminate stationary deviation against a command, the speed control loop is under 
proportional integral control. For the speed integral compensation, set the time constant of this 
integral control. Increasing the setting lowers the response level. However, if the load inertia 
moment ratio is large or the mechanical system has any vibratory element, the mechanical 
system is liable to vibrate unless the setting is increased to some degree. The guideline is as 
indicated in the following expression. 
Speed integral compensation
setting(ms)
2000 to 3000
(1   ratio of load inertia moment to 
  servo motor inertia moment setting   0.1)
Speed control gain 2 setting/
 
(2) For position control 
(a) Parameters 
The following parameters are used for gain adjustment. 
Parameter No. 
Abbreviation 
Name 
PG1 
Position control gain 1 
34 
GD2 
Ratio of load inertia moment to servo motor inertia moment 
37 
VG2 
Speed control gain 2 
38 
VIC 
Speed integral compensation 
 
(b) Adjustment procedure 
 
Step Operation 
Description 
Set an estimated value to the ratio of load inertia moment to servo motor 
inertia moment (parameter No. 34). 
 
Set a slightly smaller value to the position control gain 1 (parameter No. 
7). 
 
Increase the speed control gain 2 (parameter No. 37) within the vibration- 
and unusual noise-free range, and return slightly if vibration takes place. 
Increase the speed control gain. 
Decrease the speed integral compensation (parameter No. 38) within the 
vibration-free range, and return slightly if vibration takes place. 
Decrease the time constant of the speed 
integral compensation. 
Increase the position control gain 1 (parameter No. 7). 
Increase the position control gain. 
If the gains cannot be increased due to mechanical system resonance or 
the like and the desired response cannot be achieved, response may be 
increased by suppressing resonance with adaptive vibration suppression 
control or machine resonance suppression filter and then executing steps 
3 to 5. 
Suppression of machine resonance. 
Refer to section 9.2, 9.3. 
While checking the settling characteristic and rotational status, fine-
adjust each gain. 
Fine adjustment