11. TROUBLESHOOTING 
 
11.2 When alarm or warning has occurred 
POINT 
 
Configure up a circuit which will detect the trouble (ALM) signal and turn 
off the servo-on (SON) signal at occurrence of an alarm. 
 
11.2.1 Alarms and warning list 
When a fault occurs during operation, the corresponding alarm or warning is displayed. If any alarm or 
warning has occurred, refer to section 11.2.2 or 11.2.3 and take the appropriate action. 
Set "1      " in parameter No. 59 to output the alarm code in ON/OFF status across the corresponding 
pin and SG. Warnings (AL.90 to AL.E9) have no alarm codes. Any alarm code is output at occurrence of 
the corresponding alarm. In the normal status, the signals available before alarm code setting (CN1B-19, 
CN1A-18, CN1A-19) are output. 
After its cause has been removed, the alarm can be deactivated in any of the methods marked   in the 
alarm deactivation column. 
(Note 2) Alarm code 
Alarm deactivation 
 
Display 
CN1B-19 
pin 
CN1A-18 
pin 
CN1A-19 
pin 
Name 
Power 
OFF ON 
Press 
"SET" on 
current 
alarm 
screen. 
Alarm 
reset 
(RES) 
signal 
AL.10 0 
Undervoltage 
 
 
 
AL.12 0 
Memory 
error 
 
 
 
AL.13 0 
Clock 
error 
 
 
 
AL.15 0 
Memory 
error 
 
 
 
AL.16 1 
Encoder 
error 
 
 
 
AL.17 0 
Board 
error 
 
 
 
AL.19 0 
Memory 
error 
 
 
 
AL.1A 1 
Motor 
combination 
error 
 
 
 
AL.20 1 
Encoder 
error 
 
 
 
AL.24 
Main circuit error 
 
 
 
AL.25 1 
Absolute 
position 
erase 
 
 
 
AL.30 0 
Regenerative 
error 
 (Note 1) 
 (Note 1) 
 (Note 1)
AL.31 1 
Overspeed 
 
 
 
AL.32 1 
Overcurrent 
 
 
 
AL.33 0 
Overvoltage 
 
 
 
AL.35 
Command pulse frequency error 
 
 
 
AL.37 0 
Parameter 
error 
 
 
 
AL.45 
Main circuit device overheat 
 (Note 1) 
 (Note 1) 
 (Note 1)
AL.46 
Servo motor overheat 
 (Note 1) 
 (Note 1) 
 (Note 1)
AL.50 0 
Overload 
 (Note 1) 
 (Note 1) 
 (Note 1)
AL.51 0 
Overload 
 (Note 1) 
 (Note 1) 
 (Note 1)
AL.52 1 
Error 
excessive 
 
 
 
AL.61 1 
Home 
operation 
alarm 
 
 
 
AL.8A 
Serial communication time-out error 
 
 
 
AL.8E 
Serial communication error 
 
 
 
Alar
m
88888 0 
Watchdog 
 
 
 
AL.90 
Home position return incomplete 
AL.92 
Open battery cable warning  
AL.96 
Home position setting warning 
AL.98 Software 
limit 
warning 
AL.9F Battery 
warning 
AL.E0 Excessive 
regenerative 
warning 
AL.E1 Overload 
warning 
AL.E3 
Absolute position counter warning 
AL.E6 
Servo forced stop warning 
Wa
rni
ngs 
AL.E9 
 
Main circuit off warning 
Removing the cause of occurrence 
deactivates the alarm 
automatically. 
Note 1. Deactivate the alarm about 30 minutes of cooling time after removing the cause of occurrence. 
2. 0: Pin-SG off (open) 
    1: Pin-SG on (short)