Mitsubishi Electronics MR-J2S- CP ユーザーズマニュアル

ページ / 357
 
 
14 -  13 
14. OPTIONS AND AUXILIARY EQUIPMENT 
 
b) Control circuit terminal 
 
POINT 
 
Undertightening can cause a cable disconnection or malfunction. 
Overtightening can cause a short circuit or malfunction due to damage to 
the screw or the brake unit. 
 
A
RES
PC
B
SD
BUE
C
MSG
SD
MSG
SD SD
Jumper
 
Terminal block 
6mm
Sheath
Core
 
Wire the stripped cable after twisting to prevent the cable 
from becoming loose. In addition, do not solder it. 
Screw size: M3 
Tightening torque: 0.5N m to 0.6N m 
Cable size: 0.3mm
2
 to 0.75 mm
2
 
Screw driver: Small flat-blade screwdriver 
                       (Tip thickness: 0.4mm/Tip width 2.5mm) 
 
(c) Crimping terminals for P and N terminals of servo amplifier   
 
POINT 
 
Always use recommended crimping terminals or equivalent since some 
crimping terminals cannot be installed depending on the size. 
 
Servo amplifier 
Brake unit 
Number of 
connected 
units 
Crimping terminal
Applicable tool 
Manufacturer 
MR-J2S-350CP FR-BU2-15K 1 
 
 
 
FR-BU2-15K 1 
MR-J2S-500CP 
FR-BU2-30K 1 
FVD5.5-S4 YNT-1210S 
Japan Solderless 
Terminal 
MR-J2S-700CP FR-BU2-30K 1