Mitsubishi Electronics MR-J2S- CP ユーザーズマニュアル

ページ / 357
 
 
3 -  6 
3. SIGNALS AND WIRING 
 
Device name 
Devices 
symbol 
Connector 
pin No. 
Functions/Applications 
To start operation, short LSP-SG and/or LSN-SG. Open them to bring the motor to 
a sudden stop and make it servo-locked. 
Set "      1" in parameter No. 22 to make a slow stop. 
(Refer to section 5.2.5.) 
 
(Note) Input signal 
Operation 
 
 
LSP LSN 
CCW 
direction 
CW 
direction 
 
Forward rotation 
stroke end 
LSP CN1B 
16 
 1 
 
 
 
 0 
 
 
 
 1 
 
 
 
 0 
 
 
 
Reverse rotation stroke 
end 
LSN CN1B 
17 
 
Note. 0: LSP/LSN-SG off (open) 
1: SP/LSN-SG on (short)
 
 
Forward rotation start
 
ST1 CN1B 
1. In the case of the absolute value command system. 
When ST1-SG are shorted in the automatic operation mode, positioning is 
executed once on the basis of the position data set to the point table. 
In home position return mode, home position return starts as soon as ST1-SG 
are shorted. 
In jog operation mode, the servo motor rotates in the forward rotation direction 
while ST1-SG are shorted. 
2. In the case of the incremental value command system. 
When ST1-SG are shorted in the automatic operation mode, positioning is 
executed once on the basis of the position data set to the point table. 
In home position return mode, home position return starts as soon as ST1-SG 
are shorted. 
In jog operation mode, the servo motor rotates in the forward rotation direction 
while ST1-SG are shorted. 
Forward rotation denotes the direction in which the address is incremented. 
3. In absolute value command /incremental value command specifying system 
When ST1-SG are shorted in the automatic operation mode, positioning is 
executed once on the basis of the position data set to the point table. 
In home position return mode, home position return starts as soon as ST1-SG 
are shorted. 
In jog operation mode, the servo motor rotates in the forward rotation direction 
while ST1-SG are shorted. 
Reverse rotation start 
ST2 
CN1B 
This device is used in the incremental value command system. 
When ST2-SG are shorted in the automatic operation mode, positioning is executed 
once in the reverse rotation direction on the basis of the position data set to the 
point table. 
In jog operation mode, the servo motor rotates in the reverse rotation direction 
while ST2-SG are shorted. 
Reverse rotation denotes the direction in which the address is decremented. 
The reverse rotation start (ST2) is also used as the start signal of the function to 
perform high-speed positioning to the home position. (Refer to section 4.4.11.) 
Automatic/manual 
selection 
MD0 CN1B 
Short MD0-SG to choose the automatic operation mode, or open them to choose the 
manual operation mode. 
When terminals DOG-SG are shorted, the proximity dog signal is detected. The 
polarity of dog detection input can be changed with the parameter. 
 
Parameter No.8 
Polarity of proximity dog 
detection input 
 
 
 0     (initial value) 
DOG-SG are opened. 
 
 
 1     DOG-SG 
are 
shorted. 
 
Proximity dog 
DOG 
CN1A