Mitsubishi Electronics MR-J2S- CP ユーザーズマニュアル

ページ / 357
 
 
3 -  23 
3. SIGNALS AND WIRING 
 
2) Output pulse 
Servo motor CCW rotation
LA
LAR
LB
LBR
LZ
LZR
T
/2
400  s or more
OP
The time cycle (T) is determined by 
the setting of the parameter No. 27 and 58.
 
(4) Analog input 
Input impedance 10k to 12k  
Upper limit setting 2k
15VDC
P15R
VC‚ etc
LG
SD
2k
Servo amplifier
Approx. 
10k
 
(5) Analog output 
Output voltage  10V 
Max.1mA 
Max. output current 
Resolution : 10bits 
MO1
(MO2)
LG
SD
A
Servo amplifier
Reading in one or
both directions
1mA meter
10k