Mitsubishi Electronics MR-J2S- CP ユーザーズマニュアル

ページ / 357
 
 
3 -  38 
3. SIGNALS AND WIRING 
 
3.11 Servo amplifier terminal block (TE2) wiring method 
POINT 
 
Refer to Table 14.1 in section 14.2.1 for the wire sizes used for wiring. 
 
3.11.1 For the servo amplifier produced later than Jan. 2006 
(1)  Termination of the cables 
(a) Solid wire 
After the sheath has been stripped, the cable can be used as it is. 
Sheath
Core
Approx. 10mm
 
(b) Twisted wire 
1) When the wire is inserted directly 
Use the cable after stripping the sheath and twisting the core. At this time, take care to 
avoid a short caused by the loose wires of the core and the adjacent pole. Do not solder the 
core as it may cause a contact fault. Alternatively, a bar terminal may be used to put the 
wires together. 
 
2) When the wires are put together 
Using a bar terminal. 
 
Cable Size 
Bar Terminal Type 
[mm
2
]  AWG 
For 1 cable 
For 2 cables 
Crimping Tool 
Manufacturer 
1.25/1.5 16 AI1.5-10BK 
AI-TWIN  1.5-10BK 
2/2.5 14 
AI2.5-10BU 
 
CRIMPFOX ZA 3 
Phoenix Contact 
 
Cut the wire running out of bar terminal to less than 0.5mm.  
Less than 0.5mm
 
When using a bar terminal for two wires, insert the wires in the direction where the 
insulation sleeve does not interfere with the next pole and pressure them.  
Pressure
Pressure