Mitsubishi Electronics MR-J3 ユーザーズマニュアル

ページ / 668
 
 
3 -  57 
3. CC-LINK COMMUNICATION FUNCTIONS 
 
No.selection 1
Positioning start command
In 
position
Rough 
match
Home position 
return completion
Point table No. selection 1 (RY0A)
Forward rotation start (RY01)
Reverse rotation start (RY02)
Point table No. selection 2 (RY0B)
Point table No. selection 3 (RY0C)
Point table No. selection 4 (RY0D)
Point table No. selection 5 (RY0E)
Positioning start command
Forward rotation start request
Forward rotation start request reset
Command request time 6ms *1
Point table establishment time 4ms *1
Sets monitor code (H001) of current position 
(lower 16 bits) in RWw0.
Sets monitor code (H002) of current position 
(upper 16 bits) in RWw1.
Turns on monitor output execution demand 
(RY08).
Reads current position (Rwr0, RWr1) to D120 
and D121 when monitoring (RX08) turns on.
*1: This is when the high-speed timer limit is set to 1ms.
Setting time for the timer should be larger than the command processing 
time or twice the link scan time whichever larger. When the setting time 
is short, the command cannot be received properly.
No.selection 2
No.selection 3
No.selection 4
No.selection 5